#调峰功能 地址
#额定频率 地址
from device_conf import class_comm_device_config
import comm_remap as remap
import menu_page
from comm_device import class_comm_device
from comm_thread import class_comm_master_thread
from menu_base import class_device_menu
import menu_utils as utils
import comm_global
from enum import Enum
FREQ_ALARM_BASE = 70
USER_GLOBAL_ALARM_BASE = 32 #//Total 16 Global Alarm
USER_LOCAL_ALARM_BASE = 200 #//Total 16 Local Alarm
USER_GLOBAL_WARNING_BASE = 216 #//Total 16 Global Warning
USER_LOCAL_WARNING_BASE = 232 #//Total 16 Local Warning
#Propery of menu item
MENU_PROPERTY_READ_ONLY = 0
MENU_PROPERTY_USER = 1
MENU_PROPERTY_ENGINEER = 2
MENU_PROPERTY_WRITE_ONLY = 3
STR_SensorFailCause = "1. 传感器故障@2. 模拟量口故障@3. 通信电缆的接线不正确,或发生短路、断线"
STR_SensorFailProcess = "1. 更换传感器@2. 更换电机@3. 检查传感器是否断线或损坏。"
STR_FreqErrRef = "详见变频器说明书"
EMPTY_STRING = " "
class StrInfo(Enum) :
STR_INPUT_PASSWORD = 0, #// //请输入密码
STR_COMM_FAIL = 1, #// //通讯故障
STR_ENTER_TO_CLEAR = 2, #// //按确认清除
STR_ESC_TO_CANCEL = 3, #// //按退出取消
STR_CLEAR_FINISH = 4, #// //清除完成
STR_MIN_VALUE = 5, #//
STR_MAX_VALUE = 6, #//
STR_NO_RECORD = 7, #//
STR_VALUE_EXCEED = 8, #//
STR_SET_VALUE = 9, #//
STR_INFORM_OK = 10, #//
STR_CHECK_VOLTAGE = 11, #//
STR_CHECK_SENSOR = 12, #//
STR_CHECK_PIPE_IN = 13, #//
STR_CHECK_NONE = 14, #//
STR_CHECK_RSV = 15, #//
STR_CHECK_VOLTAGE_PHASE = 16, #//
STR_CHECK_PIPE_BROKE = 17, #//
STR_CHECK_WATER_SIGNAL = 18, #//
STR_CHECK_PID_PARA = 19, #//
STR_CHECK_HARD_ERROR = 20, #//
STR_CHECK_LOAD = 21, #//
STR_CHECK_POWER_INPUT = 22, #//
STR_CHECK_POWER_OUTPUT = 23, #//
STR_CHECK_FREQ_ACC_DEC_TIME = 24, #//
STR_CHECK_TEMPERATURE = 25, #//
STR_CHECK_FREQ_COMMUNICATE = 26, #//
STR_CHECK_MAIN_PUMP_LOST = 27, #//
STR_CHECK_FREQ_CONVERTER = 28, #//
STR_CHECK_CAN_COMM = 29, #//
STR_CHECK_FREQ_EXTERNAL_ALARM = 30, #//
STR_CHECK_FREQ_POWER = 31, #//
STR_CHECK_ALARM_RESET = 32, #//
STR_CHECK_PUMP_ID_CONFLICT = 33, #//
STR_CHECK_PRESSURE_LOW_IO = 34, #//
STR_CHECK_PRESSURE_HIGH_IO = 35, #//
STR_CHECK_WATER_CONTAINER_SIGNAL = 36, #//
STR_CHECK_MOTOR_TEMPERATURE_OR_SENSOR = 37, #//
STR_CHECK_BUS_POWER_SHORT = 38, #//
STR_PUMP_NOT_FOUNT = 39, #//
STR_PUMP_UPDATE_FAIL = 40, #//
STR_PUMP_UPDATE_SUCCESS = 41, #//
STR_PUMP_UPDATE_TIMEOUT = 42, #//
STR_PUMP_READ_FAIL = 43, #//
STR_PUMP_READ_SUCCESS = 44, #//
STR_PUMP_READ_TIMEOUT = 45, #//
class AlarmInfo(Enum) :
ALARM_FREE = 0,
ALARM_PIPE_BROKE = 1, #//爆管保护
ALARM_NO_WATER_EXIST = 2, #//无水停机
ALARM_WATER_PRESSURE_HIGH = 3, #//水压过高保护
ALARM_OVER_VOLTAGE = 4, #//供电电压过高
ALARM_UNDER_VOLTAGE = 5, #//供电电压过低
ALARM_BOARD_HARDWARE = 6, #//硬件故障
ALARM_IO_NO_WATER_EXIST = 7, #//市政或水箱无水停机
#//传感器故障子故障
ALARM_SENSOR_PRESS_IN = 8, #//入口压力传感器故障
ALARM_SENSOR_PRESS_OUT = 9, #//出口压力传感器故障
ALARM_SENSOR_FLUX = 10, #//流量传感器故障
ALARM_SENSOR_PH = 11, #//PH值传感器故障
ALARM_SENSOR_WATER_CLEAR = 12, #//浊度传感器故障
ALARM_SENSOR_REMAIN_CL = 13, #//余氯传感器故障
ALARM_NEG_PRESSURE = 14, #//负压报警
ALARM_VACUMM_PRESSURE = 15, #//真空报警
ALARM_SENSOR_WATER_LEVEL = 16, #//水位传感器故障
ALARM_WATER_PRESSURE_LOW = 17, #//水位过低提示
ALARM_SENSOR_FLUX_IN = 18, #//输入流量传感器故警
ALARM_SENSOR_IN_VALVE_FEEDBACK = 19, #//输入阀反馈
ALARM_SENSOR_NOIZE = 20,
ALARM_SENSOR_HUMIDITY = 21,
ALARM_IO_LEAK_WATER = 22,
ALARM_IO_SMOKE = 23,
ALARM_IO_EXTERNALERROR = 24, #//外部故障
ALARM_SENSOR_WATER_LEVEL2 = 25, #//水位传感器2故障
ALARM_SENSOR_IN_VALVE_FEEDBACK2 = 26, #//开度反馈传感器2故障
ALARM_SENSOR_TEMPERATURE = 27, #//温度传感器故障
ALARM_SENSOR_TEMPERATURE2 = 28, #//站内温度传感器故障
ALARM_SENSOR_TEMPERATURE3 = 29, #//夹层温度传感器故障
ALARM_SENSOR_WATER_LEVEL3 = 30,
USER_GLOBAL_ALARM_0 = USER_GLOBAL_ALARM_BASE + 0, #水箱液位低报警
USER_GLOBAL_ALARM_1 = USER_GLOBAL_ALARM_BASE + 1,
USER_GLOBAL_ALARM_2 = USER_GLOBAL_ALARM_BASE + 2,
USER_GLOBAL_ALARM_3 = USER_GLOBAL_ALARM_BASE + 3,
USER_GLOBAL_ALARM_4 = USER_GLOBAL_ALARM_BASE + 4,
USER_GLOBAL_ALARM_5 = USER_GLOBAL_ALARM_BASE + 5,
USER_GLOBAL_ALARM_6 = USER_GLOBAL_ALARM_BASE + 6,
USER_GLOBAL_ALARM_7 = USER_GLOBAL_ALARM_BASE + 7,
USER_GLOBAL_ALARM_8 = USER_GLOBAL_ALARM_BASE + 8,
USER_GLOBAL_ALARM_9 = USER_GLOBAL_ALARM_BASE + 9,
USER_GLOBAL_ALARM_10 = USER_GLOBAL_ALARM_BASE + 10,
USER_GLOBAL_ALARM_11 = USER_GLOBAL_ALARM_BASE + 11,
USER_GLOBAL_ALARM_12 = USER_GLOBAL_ALARM_BASE + 12,
USER_GLOBAL_ALARM_13 = USER_GLOBAL_ALARM_BASE + 13,
USER_GLOBAL_ALARM_14 = USER_GLOBAL_ALARM_BASE + 14,
USER_GLOBAL_ALARM_15 = USER_GLOBAL_ALARM_BASE + 15,
#//每台泵子故障
ALARM_COMM_FREQ_CONVERTER = 54, #//变频器通讯故障
ALARM_COMM_TOUCH_BOARD = 55, #//触控板通讯故障
ALARM_COMM_MAIN_BOARD = 56, #//主控板通讯故障
ALARM_PUMP_AIR_SWITCH_OFF = 57, #//空开跳闸
ALARM_MAIN_PUMP_LOST = 58, #//主泵丢失
ALARM_PUMP_RESET_DELAY = 59, #//泵处于故障复位状态
ALARM_COMMAND_EXECUTE_FAIL = 60, #//泵命令执行失败
ALARM_FREQ_PARAMETER_SET = 61, #//变频参数设置故障
ALARM_PUMP_ADDR_ID_CONFLICT = 62, #//泵号冲突
ALARM_PUMP_MOTOR_TEMPERATURE_HIGH = 63,
ALARM_BUS_POWER_SHORT = 64, #//总线电源短路
ALARM_POWER_LOST = 65, #//电源丢失
ALARM_AUTO_REMOTE_DISABLE = 66, #//自动停止信号有效
ALARM_FREQ_U_PROTECT = FREQ_ALARM_BASE + 0, #//变频器U相保护
ALARM_FREQ_V_PROTECT = FREQ_ALARM_BASE + 1, #//变频器V相保护
ALARM_FREQ_W_PROTECT = FREQ_ALARM_BASE + 2, #//变频器W相保护
ALARM_FREQ_ACCELERATE_OVER_CURRENT = FREQ_ALARM_BASE + 3, #//变频器加速过流
ALARM_FREQ_DECELERATE_OVER_CURRENT = FREQ_ALARM_BASE + 4, #//变频器减速过流
ALARM_FREQ_FIX_SPEED_OVER_CURRENT = FREQ_ALARM_BASE + 5, #//变频器恒速过流
ALARM_FREQ_ACCELERATE_OVER_VOLTAGE = FREQ_ALARM_BASE + 6, #//变频器加速过电压
ALARM_FREQ_DECELERATE_OVER_VOLTAGE = FREQ_ALARM_BASE + 7, #//变频器减速过电压
ALARM_FREQ_FIX_SPEED_OVER_VOLTAGE = FREQ_ALARM_BASE + 8, #//变频器恒速过电压
ALARM_FREQ_DC_VOLTAGE_LOW = FREQ_ALARM_BASE + 9, #//变频器母线电压低
ALARM_FREQ_MOTOR_OVER_LOAD = FREQ_ALARM_BASE + 10, #//变频器电机过热
ALARM_FREQ_OVER_LOAD = FREQ_ALARM_BASE + 11, #//变频器过载
ALARM_FREQ_INPUT_MISS_PHASE = FREQ_ALARM_BASE + 12, #//变频器输入缺相
ALARM_FREQ_OUTPUT_MISS_PHASE = FREQ_ALARM_BASE + 13, #//变频器输出缺相
ALARM_FREQ_MODULE_TEMP_HIGH = FREQ_ALARM_BASE + 14, #//变频器温度过高
ALARM_FREQ_RSV45 = FREQ_ALARM_BASE + 15, #//保留
ALARM_FREQ_EXTERNAL = FREQ_ALARM_BASE + 16, #//变频器外部故障
ALARM_FREQ_COMMUNICATION = FREQ_ALARM_BASE + 17, #//变频器通讯故障
ALARM_FREQ_CURRENT_MEASURE = FREQ_ALARM_BASE + 18, #//变频器电流检测回路故障
ALARM_FREQ_SELF_STUDY = FREQ_ALARM_BASE + 19, #//变频器学习故障
ALARM_FREQ_EEPROM = FREQ_ALARM_BASE + 20, #//变频器EEPROM故障
ALARM_FREQ_PID_FAIL = FREQ_ALARM_BASE + 21, #//变频器PID调节故障
ALARM_FREQ_STOP_UNIT = FREQ_ALARM_BASE + 22, #//变频器制动单元故障
ALARM_FREQ_RSV53 = FREQ_ALARM_BASE + 23, #//保留
ALARM_FREQ_SHORT_GROUND = FREQ_ALARM_BASE + 24, #//变频器对地短路
#// V1000C变频器故障
#// ALARM_FREQ_MEMOBUS = 100, #//CE (MEMOBUS通信故障) #// AlarmStatus5.MEMOBUSCommuFault, MinorAlarm1.CommAlarm, AlarmStatus1.CommAlarm, MinorAlarm3.CommunicationErr
ALARM_FREQ_CONTROL_FAULT = 101, #// CF (控制故障) #// AlarmStatus5.ControlFault
ALARM_FREQ_CURRENT_BASE = 102, #// CoF 电流偏<E6B581>?故障<E69585>? #// AlarmStatus7.CurrentBiasFault
ALARM_FREQ_ADC_FAULT = 103, #// CPF02 A/D <20>?换器故障<E69585>?
ALARM_FREQ_PWM_DATA_ERR = 104, #// CPF03 PWM 数据异常<E5BC82>?
ALARM_FREQ_EEPROM_DATA_ERR = 105, #// CPF06 EEPROM 数据异常<E5BC82>?
ALARM_FREQ_TERMINAL_FAULT = 106, #// CPF07 <>??子电<E5AD90>?板通信故障<E69585>?
ALARM_FREQ_EEPROM_COMM_FAULT = 107, #// CPF08 EEPROM 串<>?<3F>通信故障<E69585>?
ALARM_FREQ_RAM_FAULT = 108, #// CPF11 RAM 故障<E69585>?
ALARM_FREQ_FLASH_FAULT = 109, #// CPF12 (闪存故障)
ALARM_FREQ_MONITOR = 110, #// CPF13 (监视故障) #//
ALARM_FREQ_CTRL_CIRCUIT = 111, #// CPF14 控制回<E588B6>?故障<E69585>?
ALARM_FREQ_CLOCK_FAULT = 112, #// CPF16 (时钟故障)
ALARM_FREQ_INTERRUPT_FAULT = 113, #// CPF17 <EFBC88>?故障<E69585>?
ALARM_FREQ_PWM_FBDATA_ERR = 114, #// CPF23 PWM 反<>?<3F><EFBFBD>?异常<E5BC82>?
ALARM_FREQ_CAPACITY_SIGNAL = 115, #// CPF24 变频器容量信号故障<E69585>?
ALARM_FREQ_TERMINAL_NOT_CONNECT = 116, #// CPF25 未连接<E8BF9E>?子电<E5AD90>?板)
ALARM_FREQ_MONITOR_DEVICE = 117, #// E5/CPF13 监视<E79B91>?<3F>置故障<E69585>?
ALARM_FREQ_EXTERN_FAULT_S1 = 118, #// EF1 <>?<3F>部故<E983A8>??输入<E8BE93>??<3F>?S1#// AlarmStatus7.ExternalFault1, MinorAlarm5.ExternalFault1
ALARM_FREQ_EXTERN_FAULT_S2 = 119, #// EF2 <>?<3F>部故<E983A8>??输入<E8BE93>??<3F>?S2#// AlarmStatus7.ExternalFault2, MinorAlarm5.ExternalFault2
ALARM_FREQ_EXTERN_FAULT_S3 = 120, #// EF3 <>?<3F>部故<E983A8>??输入<E8BE93>??<3F>?S3#// AlarmStatus4.ExternalFault3, MinorAlarm2.ExternalFault3
ALARM_FREQ_EXTERN_FAULT_S4 = 121, #// EF4 <>?<3F>部故<E983A8>??输入<E8BE93>??<3F>?S4#// AlarmStatus4.ExternalFault4, MinorAlarm2.ExternalFault4
ALARM_FREQ_EXTERN_FAULT_S5 = 122, #// EF5 <>?<3F>部故<E983A8>??输入<E8BE93>??<3F>?S5#// AlarmStatus4.ExternalFault5, MinorAlarm2.ExternalFault5
ALARM_FREQ_EXTERN_FAULT_S6 = 123, #// EF6 <>?<3F>部故<E983A8>??输入<E8BE93>??<3F>?S6#// AlarmStatus4.ExternalFault6, MinorAlarm2.ExternalFault6
ALARM_FREQ_EEPROMW_WRITE_ERR = 124, #// Err EEPROM 写入不当<E4B88D>?#// AlarmStatus4.EEPROMWriteError
ALARM_FREQ_PIDFB_OVERTOP = 125, #// FbH PID 反<>?<3F>超值 #// AlarmStatus7.PIDFeedbackOvertop, MinorAlarm4.PIDFeedbackOvertop
ALARM_FREQ_PID_FB_LOST = 126, #// FbL PID 反丧<E58F8D>?/ AlarmStatus5.PID_FeedbackLost, MinorAlarm4.PID_FeedbackLost
ALARM_FREQ_GROUND_FALUT = 127, #// GF 接地短<E59CB0>?<3F>?
ALARM_FREQ_OUT_PHASE_LOST = 128, #// LF (输出缺相)
ALARM_FREQ_OUT_IMBALANCE = 129, #// LF2 (输出电流失衡)
ALARM_FREQ_NODE_SETUP_ERR = 130, #// nSENode Setup 故障<E69585>?
ALARM_FREQ_OVER_CURRENT = 131, #// oC 过电流<E794B5>?
ALARM_FREQ_FIN_OVER_HEAT = 132, #// oH/oH1 <EFBC88>?片过<E78987>?<3F>?
ALARM_FREQ_MOTOR_OVERHEAT1 = 133, #// oH3 电机过<E69CBA>?警<>??PTC 输入))
ALARM_FREQ_MOTOR_OVERHEAT2 = 134, #// oH4 电机过<E69CBA>?故<>??PTC 输入))
ALARM_FREQ_MOTOR_OVERLOAD = 135, #// oL1 (电机过载)
ALARM_FREQ_VFD_OVERLOAD = 136, #// oL2 变频器过载<E8BF87>?
ALARM_FREQ_OVER_TORQUE1 = 137, #// oL3 <EFBC88>?矩<>?<3F><>?1<>?
ALARM_FREQ_OVER_TORQUE2 = 138, #// oL4 <EFBC88>?矩<>?<3F><>?2<>?
ALARM_FREQ_MECHAN_AGING1 = 139, #// oL5 机械老化检<E58C96>?1<>?
ALARM_FREQ_BREAK_OVERLOAD = 140, #// oL7 高滑差制动电机过载保护<E4BF9D>?
ALARM_FREQ_OVER_VOLTAGE = 141, #// ov (主回路过电压)
ALARM_FREQ_VOLTAGE_FAULT = 142, #// PF 主回路电压故障<E69585>?
ALARM_FREQ_BRAKE_TRANS = 143, #// rr <EFBC88>?制动晶体管故障<E69585>??
ALARM_FREQ_OUT_SHORT = 144, #// SC 输出短<E587BA>?或IGBT故障<E69585>?
ALARM_FREQ_SPEED_SEARCH = 145, #// SEr 速度搜索重试故障<E69585>?
ALARM_FREQ_DISORDER = 146, #// STo 失调<E5A4B1>?<3F>
ALARM_FREQ_LACK_OF_TORQUE1 = 147, #// UL3 转矩不<E79FA9>?1<>?
ALARM_FREQ_LACK_OF_TORQUE2 = 148, #// UL4 转矩不<E79FA9>?2<>?
ALARM_FREQ_MECHAN_AGING2 = 149, #// UL5 机械老化检<E58C96>?2<>?
ALARM_FREQ_MAJOR_UNDERVOLTAGE = 150, #// Uv/Uv1 (主回路欠电压)
ALARM_FREQ_CTRL_POW_FAULT = 151, #// Uv2 (控制电源故障)
ALARM_FREQ_PREVENT_SHOCK = 152, #// Uv3 冲击防止回<E6ADA2>?故障<E69585>?
ALARM_FREQ_CONTROL1_ERR = 153, #//CPF18
ALARM_FREQ_CONTROL2_ERR = 154, #//CPF19
ALARM_FREQ_HARD1_ERR = 155, #//CPF20
ALARM_FREQ_HARD2_ERR = 156, #//CPF21
ALARM_FREQ_ADC_ERR = 157, #//CPF22
ALARM_FREQ_BASE_BLOCK = 160, #// 变频器基极封锁(bb)
ALARM_FREQ_COMM_WAITING = 161, #// 通信等待中(CALL)
ALARM_FREQ_RST_WHEN_RUN = 162, #// 运行指令输入中复位(CrST)
ALARM_FREQ_COMM_CYCLE_ERR = 163, #// 通信周期设定错误(CyC)
ALARM_FREQ_DRIVE_DISABLE = 164, #// Drive Disable中(dnE)
ALARM_FREQ_CW_CCW_CMD = 165, #// 正反转指令同时输入(EF)
ALARM_FREQ_CURRENT_WARNING = 166, #// 电流警告(HCA)
ALARM_FREQ_MAINTAIN_FAN = 167, #// 冷却风扇维护时期(LT-1)
ALARM_FREQ_MAINTAIN_CAP = 168, #// 电容器维护时期(LT-2)
ALARM_FREQ_MAINTAIN_RELAY = 169, #// 冲击电流防止继电器维护时期(LT-3)
ALARM_FREQ_MAINTAIN_IGBT_50 = 170, #// IGBT维护时期(50%)(LT-4)
ALARM_FREQ_VFD_OH_ALERT = 171, #// 变频器过热预警(oH2)
ALARM_FREQ_MOTOR_OVERHEAT = 172, #// 电机过热(oH3)
ALARM_FREQ_RSV173 = 173, #// 保留
ALARM_FREQ_RSV174 = 174, #// 保留
ALARM_FREQ_MOBUS_TEST_OK = 175, #// MEMOBUS通信测试模式正常(PASS)
ALARM_FREQ_SWITCH_WHEN_RUN = 176, #// 运行中输入电机切换指令(rUn)
ALARM_FREQ_MOBUS_TEST_ERR = 177, #// MEMOBUS通信测试模式故障(SE)
ALARM_FREQ_MAINTAIN_IGBT_90 = 178, #// IGBT维护时期(90%)(TrPC)
ALARM_FREQ_RSV179 = 179, #// 保留
ALARM_FREQ_RSV180 = 180, #// 保留
ALARM_FREQ_CAPACITY_SET_ERR = 181, #// oPE01 变频器容量的设定故障(oPE01)
ALARM_FREQ_PARA_RANGE_ERR = 182, #// oPE02 参数设定范围不当(oPE02)
ALARM_FREQ_DIN_SELECT_ERR = 183, #// oPE03 多功能输入的选择不当(oPE03)
ALARM_FREQ_AIN_SELECT_ERR = 184, #// oPE07 多功能模拟量输入的选择不当(oPE07)
ALARM_FREQ_PARA_SELECT_ERR = 185, #// oPE08 参数选择不当(oPE08)
ALARM_FREQ_PID_SELECT_ERR = 186, #// oPE09 PID控制的选择不当(oPE09)
ALARM_FREQ_VF_DATA_SET_ERR = 187, #// oPE10 V/f数据的设定不当(oPE10)
ALARM_FREQ_CARRIER_SET_ERR = 188, #// oPE11 载波频率的设定不当(oPE11)
USER_LOCAL_ALARM_0 = USER_LOCAL_ALARM_BASE + 0,
USER_LOCAL_ALARM_1 = USER_LOCAL_ALARM_BASE + 1,
USER_LOCAL_ALARM_2 = USER_LOCAL_ALARM_BASE + 2,
USER_LOCAL_ALARM_3 = USER_LOCAL_ALARM_BASE + 3,
USER_LOCAL_ALARM_4 = USER_LOCAL_ALARM_BASE + 4,
USER_LOCAL_ALARM_5 = USER_LOCAL_ALARM_BASE + 5,
USER_LOCAL_ALARM_6 = USER_LOCAL_ALARM_BASE + 6,
USER_LOCAL_ALARM_7 = USER_LOCAL_ALARM_BASE + 7,
USER_LOCAL_ALARM_8 = USER_LOCAL_ALARM_BASE + 8,
USER_LOCAL_ALARM_9 = USER_LOCAL_ALARM_BASE + 9,
USER_LOCAL_ALARM_10 = USER_LOCAL_ALARM_BASE + 10,
USER_LOCAL_ALARM_11 = USER_LOCAL_ALARM_BASE + 11,
USER_LOCAL_ALARM_12 = USER_LOCAL_ALARM_BASE + 12,
USER_LOCAL_ALARM_13 = USER_LOCAL_ALARM_BASE + 13,
USER_LOCAL_ALARM_14 = USER_LOCAL_ALARM_BASE + 14,
USER_LOCAL_ALARM_15 = USER_LOCAL_ALARM_BASE + 15,
USER_GLOBAL_WARNING_0 = USER_GLOBAL_WARNING_BASE + 0,
USER_GLOBAL_WARNING_1 = USER_GLOBAL_WARNING_BASE + 1,
USER_GLOBAL_WARNING_2 = USER_GLOBAL_WARNING_BASE + 2,
USER_GLOBAL_WARNING_3 = USER_GLOBAL_WARNING_BASE + 3,
USER_GLOBAL_WARNING_4 = USER_GLOBAL_WARNING_BASE + 4,
USER_GLOBAL_WARNING_5 = USER_GLOBAL_WARNING_BASE + 5,
USER_GLOBAL_WARNING_6 = USER_GLOBAL_WARNING_BASE + 6,
USER_GLOBAL_WARNING_7 = USER_GLOBAL_WARNING_BASE + 7,
USER_GLOBAL_WARNING_8 = USER_GLOBAL_WARNING_BASE + 8,
USER_GLOBAL_WARNING_9 = USER_GLOBAL_WARNING_BASE + 9,
USER_GLOBAL_WARNING_10 = USER_GLOBAL_WARNING_BASE + 10,
USER_GLOBAL_WARNING_11 = USER_GLOBAL_WARNING_BASE + 11,
USER_GLOBAL_WARNING_12 = USER_GLOBAL_WARNING_BASE + 12,
USER_GLOBAL_WARNING_13 = USER_GLOBAL_WARNING_BASE + 13,
USER_GLOBAL_WARNING_14 = USER_GLOBAL_WARNING_BASE + 14,
USER_GLOBAL_WARNING_15 = USER_GLOBAL_WARNING_BASE + 15,
USER_LOCAL_WARNING_0 = USER_LOCAL_WARNING_BASE + 0,
USER_LOCAL_WARNING_1 = USER_LOCAL_WARNING_BASE + 1,
USER_LOCAL_WARNING_2 = USER_LOCAL_WARNING_BASE + 2,
USER_LOCAL_WARNING_3 = USER_LOCAL_WARNING_BASE + 3,
USER_LOCAL_WARNING_4 = USER_LOCAL_WARNING_BASE + 4,
USER_LOCAL_WARNING_5 = USER_LOCAL_WARNING_BASE + 5,
USER_LOCAL_WARNING_6 = USER_LOCAL_WARNING_BASE + 6,
USER_LOCAL_WARNING_7 = USER_LOCAL_WARNING_BASE + 7,
USER_LOCAL_WARNING_8 = USER_LOCAL_WARNING_BASE + 8,
USER_LOCAL_WARNING_9 = USER_LOCAL_WARNING_BASE + 9,
USER_LOCAL_WARNING_10 = USER_LOCAL_WARNING_BASE + 10,
USER_LOCAL_WARNING_11 = USER_LOCAL_WARNING_BASE + 11,
USER_LOCAL_WARNING_12 = USER_LOCAL_WARNING_BASE + 12,
USER_LOCAL_WARNING_13 = USER_LOCAL_WARNING_BASE + 13,
USER_LOCAL_WARNING_14 = USER_LOCAL_WARNING_BASE + 14,
USER_LOCAL_WARNING_15 = USER_LOCAL_WARNING_BASE + 15,
ALARM_MAX = 0x8000,
alias_table = [
{"alias_str" : {
StrInfo.STR_INPUT_PASSWORD: "请输入密码",
StrInfo.STR_COMM_FAIL : "通讯故障", #// //通讯故障
StrInfo.STR_ENTER_TO_CLEAR : "按确认清除", #// //按确认清除
StrInfo.STR_ESC_TO_CANCEL : "按退出取消", #// //按退出取消
StrInfo.STR_CLEAR_FINISH : "清除完成", #// //清除完成
StrInfo.STR_MIN_VALUE : "最小值", #//
StrInfo.STR_MAX_VALUE : "最大值", #//
StrInfo.STR_NO_RECORD : "无记录", #//
StrInfo.STR_VALUE_EXCEED : "设定值越限", #//
StrInfo.STR_SET_VALUE : "设定值", #//
StrInfo.STR_INFORM_OK : "通知正常", #//
StrInfo.STR_CHECK_VOLTAGE : "检测输入电压", #//
StrInfo.STR_CHECK_SENSOR : "检测传感器", #//
StrInfo.STR_CHECK_PIPE_IN : "检测输入管道", #//
StrInfo.STR_CHECK_NONE : "无需处理", #//
StrInfo.STR_CHECK_RSV : "未知故障, 请咨询设备厂家", #//
StrInfo.STR_CHECK_VOLTAGE_PHASE : "电压相序故障", #//
StrInfo.STR_CHECK_PIPE_BROKE : "检查爆管", #//
StrInfo.STR_CHECK_WATER_SIGNAL : "检查水位型号", #//
StrInfo.STR_CHECK_PID_PARA : "检查PID参数, 或流量变化过大", #//
StrInfo.STR_CHECK_HARD_ERROR : "尝试重启, 如无效需寄回原厂返修", #//
StrInfo.STR_CHECK_LOAD : "检查水泵负载情况", #//
StrInfo.STR_CHECK_POWER_INPUT : "检查三相电源输入接线情况", #//
StrInfo.STR_CHECK_POWER_OUTPUT : "检查三相电源输出接线是否短路", #//
StrInfo.STR_CHECK_FREQ_ACC_DEC_TIME : "检查变频器加速或减速时间是否过小", #//
StrInfo.STR_CHECK_TEMPERATURE : "检查变频器通风散热情况", #//
StrInfo.STR_CHECK_FREQ_COMMUNICATE : "检查本台水泵供电是否正常", #//
StrInfo.STR_CHECK_MAIN_PUMP_LOST : "检查CAN通讯线连接. 检查1号泵是否存在", #//
StrInfo.STR_CHECK_FREQ_CONVERTER : "检查变频器是否允许通讯", #//
StrInfo.STR_CHECK_CAN_COMM : "检查CAN通讯", #//
StrInfo.STR_CHECK_FREQ_EXTERNAL_ALARM : "检查变频器与主控板接口线", #//
StrInfo.STR_CHECK_FREQ_POWER : "检查变频器供电情况", #//
StrInfo.STR_CHECK_ALARM_RESET : "故障复位中,请稍候", #//
StrInfo.STR_CHECK_PUMP_ID_CONFLICT : "检查CAN地址冲突", #//
StrInfo.STR_CHECK_PRESSURE_LOW_IO : "检查电压力节点低", #//
StrInfo.STR_CHECK_PRESSURE_HIGH_IO : "检查电压力节点高", #//
StrInfo.STR_CHECK_WATER_CONTAINER_SIGNAL : "检查水箱信号", #//
StrInfo.STR_CHECK_MOTOR_TEMPERATURE_OR_SENSOR : "电机温度过高,检查电机散热风扇或水冷回路是否正常", #//
StrInfo.STR_CHECK_BUS_POWER_SHORT : "检查总线电源是否存在短路", #//
StrInfo.STR_PUMP_NOT_FOUNT : "泵没有找到", #//
StrInfo.STR_PUMP_UPDATE_FAIL : "泵数据更新失败", #//
StrInfo.STR_PUMP_UPDATE_SUCCESS : "泵数据更新成功", #//
StrInfo.STR_PUMP_UPDATE_TIMEOUT : "泵数据更新超时", #//
StrInfo.STR_PUMP_READ_FAIL : "泵数据读取失败", #//
StrInfo.STR_PUMP_READ_SUCCESS : "泵数据读取成功", #//
StrInfo.STR_PUMP_READ_TIMEOUT : "泵数据读取超时", #//
}},
{"alias_alarm_str":
{
AlarmInfo.ALARM_FREE : "无故障",
AlarmInfo.ALARM_PIPE_BROKE : "爆管保护",
AlarmInfo.ALARM_NO_WATER_EXIST : "市政或水箱无水停机",
AlarmInfo.ALARM_WATER_PRESSURE_HIGH : "超压保护",
AlarmInfo.ALARM_OVER_VOLTAGE : "供电电压过高",
AlarmInfo.ALARM_UNDER_VOLTAGE : "供电电压过低",
AlarmInfo.ALARM_BOARD_HARDWARE : "硬件故障",
AlarmInfo.ALARM_IO_NO_WATER_EXIST : "IO无水停机",
AlarmInfo.ALARM_SENSOR_PRESS_IN : "入口压力传感器故障",
AlarmInfo.ALARM_SENSOR_PRESS_OUT : "出口压力传感器故障",
AlarmInfo.ALARM_SENSOR_FLUX : "流量传感器故障",
AlarmInfo.ALARM_SENSOR_PH : "PH值传感器故障",
AlarmInfo.ALARM_SENSOR_WATER_CLEAR : "浊度传感器故障",
AlarmInfo.ALARM_SENSOR_REMAIN_CL : "余氯传感器故障",
AlarmInfo.ALARM_NEG_PRESSURE : "负压保护",
AlarmInfo.ALARM_VACUMM_PRESSURE : "真空保护",
AlarmInfo.ALARM_SENSOR_WATER_LEVEL : "液位1传感器故障",
AlarmInfo.ALARM_WATER_PRESSURE_LOW : "电接点压力低信号有效",
AlarmInfo.ALARM_SENSOR_FLUX_IN : "输入流量传感器故障",
AlarmInfo.ALARM_SENSOR_IN_VALVE_FEEDBACK : "输入阀反馈故障",
AlarmInfo.ALARM_SENSOR_NOIZE : "噪音传感器故障",
AlarmInfo.ALARM_SENSOR_HUMIDITY : "湿度传感器故障",
AlarmInfo.ALARM_SENSOR_WATER_LEVEL2 : "液位2传感器故障",
AlarmInfo.ALARM_SENSOR_IN_VALVE_FEEDBACK2 : "开度反馈2传感器故障",
AlarmInfo.ALARM_IO_LEAK_WATER : "漏水报警",
AlarmInfo.ALARM_IO_SMOKE : "烟感报警",
AlarmInfo.ALARM_IO_EXTERNALERROR : "外部故障报警",
AlarmInfo.ALARM_SENSOR_HUMIDITY : "湿度传感器故障",
AlarmInfo.ALARM_SENSOR_TEMPERATURE : "水温传感器故障",
AlarmInfo.ALARM_SENSOR_TEMPERATURE2 : "站内温度传感器故障",
AlarmInfo.ALARM_SENSOR_TEMPERATURE3 : "夹层温度传感器故障",
AlarmInfo.ALARM_SENSOR_WATER_LEVEL3 : "液位3传感器故障",
AlarmInfo.ALARM_COMM_FREQ_CONVERTER : "变频器通讯故障",
AlarmInfo.ALARM_COMM_TOUCH_BOARD : "触控板通讯故障",
AlarmInfo.ALARM_COMM_MAIN_BOARD : "主控板通讯故障",
AlarmInfo.ALARM_PUMP_AIR_SWITCH_OFF : "空开跳闸",
AlarmInfo.ALARM_MAIN_PUMP_LOST : "主泵丢失",
AlarmInfo.ALARM_PUMP_RESET_DELAY : "泵处于故障复位状态",
AlarmInfo.ALARM_COMMAND_EXECUTE_FAIL : "泵命令执行失败",
AlarmInfo.ALARM_FREQ_PARAMETER_SET : "变频器参数设置故障",
AlarmInfo.ALARM_PUMP_ADDR_ID_CONFLICT : "泵号冲突",
AlarmInfo.ALARM_PUMP_MOTOR_TEMPERATURE_HIGH : "电机温度过高",
AlarmInfo.ALARM_BUS_POWER_SHORT : "通信电源短路",
AlarmInfo.ALARM_POWER_LOST : "本机内部失电",
AlarmInfo.ALARM_FREQ_U_PROTECT : "变频器U相保护", #//"30 //STR_ALARM_FREQ_U_PROTECT
AlarmInfo.ALARM_FREQ_V_PROTECT : "变频器V相保护", #//"31 //STR_ALARM_FREQ_V_PROTECT
AlarmInfo.ALARM_FREQ_W_PROTECT : "变频器W相保护", #//"32 //STR_ALARM_FREQ_W_PROTECT
AlarmInfo.ALARM_FREQ_ACCELERATE_OVER_CURRENT : "变频器加速过流保护", #//"33 //STR_ALARM_FREQ_ACCELERATE_OVER_CURRENT
AlarmInfo.ALARM_FREQ_DECELERATE_OVER_CURRENT : "变频器减速过流保护", #//"34 //STR_ALARM_FREQ_DECELERATE_OVER_CURRENT
AlarmInfo.ALARM_FREQ_FIX_SPEED_OVER_CURRENT : "变频器定速过流保护", #//"35 //STR_ALARM_FREQ_FIX_SPEED_OVER_CURRENT
AlarmInfo.ALARM_FREQ_ACCELERATE_OVER_VOLTAGE : "变频器加速过压保护", #//"36 //STR_ALARM_FREQ_ACCELERATE_OVER_VOLTAGE
AlarmInfo.ALARM_FREQ_DECELERATE_OVER_VOLTAGE : "变频器减速过压保护", #//"37 //STR_ALARM_FREQ_DECELERATE_OVER_VOLTAGE
AlarmInfo.ALARM_FREQ_FIX_SPEED_OVER_VOLTAGE : "变频器定速过压保护", #//"38 //STR_ALARM_FREQ_FIX_SPEED_OVER_VOLTAGE
AlarmInfo.ALARM_FREQ_DC_VOLTAGE_LOW : "变频器母线电压低", #//"39 //STR_ALARM_FREQ_DC_VOLTAGE_LOW
AlarmInfo.ALARM_FREQ_MOTOR_OVER_LOAD : "变频器电机过载", #//"40 //STR_ALARM_FREQ_MOTOR_OVER_LOAD
AlarmInfo.ALARM_FREQ_OVER_LOAD : "变频器过载", #//"41 //STR_ALARM_FREQ_OVER_LOAD
AlarmInfo.ALARM_FREQ_INPUT_MISS_PHASE : "变频器输入缺相", #//"42 //STR_ALARM_FREQ_INPUT_MISS_PHASE
AlarmInfo.ALARM_FREQ_OUTPUT_MISS_PHASE : "变频器输出缺相", #//"43 //STR_ALARM_FREQ_OUTPUT_MISS_PHASE
AlarmInfo.ALARM_FREQ_MODULE_TEMP_HIGH : "变频器温度过高", #//"44 //STR_ALARM_FREQ_MODULE_TEMP_HIGH
AlarmInfo.ALARM_FREQ_RSV45 : "保留", #//"45 //STR_ALARM_FREQ_RSV45
AlarmInfo.ALARM_FREQ_EXTERNAL : "变频器外部故障", #//"46 //STR_ALARM_FREQ_EXTERNAL
AlarmInfo.ALARM_FREQ_COMMUNICATION : "变频器通讯故障", #//"47 //STR_ALARM_FREQ_COMMUNICATION
AlarmInfo.ALARM_FREQ_CURRENT_MEASURE : "变频器电流检测回路故障", #//"48 //STR_ALARM_FREQ_CURRENT_MEASURE
AlarmInfo.ALARM_FREQ_SELF_STUDY : "变频器自学习故障", #//"49 //STR_ALARM_FREQ_SELF_STUDY
AlarmInfo.ALARM_FREQ_EEPROM : "变频器EEPROM故障", #//"50 //STR_ALARM_FREQ_EEPROM
AlarmInfo.ALARM_FREQ_PID_FAIL : "变频器PID调节故障", #//"51 //STR_ALARM_FREQ_PID_FAIL
AlarmInfo.ALARM_FREQ_STOP_UNIT : "变频器制动单元故障", #//"52 //STR_ALARM_FREQ_STOP_UNIT
AlarmInfo.ALARM_FREQ_RSV53 : "保留", #//"53 //STR_ALARM_FREQ_RSV53
AlarmInfo.ALARM_FREQ_CURRENT_BASE : "电流偏置故障(CoF)", # //102
AlarmInfo.ALARM_FREQ_ADC_FAULT : "A/D 转换器故障(CPF02)", # //103
AlarmInfo.ALARM_FREQ_PWM_DATA_ERR : "PWM 数据异常(CPF03)", # //104
AlarmInfo.ALARM_FREQ_EEPROM_DATA_ERR : "EEPROM 数据异常(CPF06)", # //105
AlarmInfo.ALARM_FREQ_TERMINAL_FAULT : "端子电路板通信故障(CPF07)", # //106
AlarmInfo.ALARM_FREQ_EEPROM_COMM_FAULT : "EEPROM 串行通信故障(CPF08)", # //107
AlarmInfo.ALARM_FREQ_RAM_FAULT : "RAM 故障(CPF11)", # //108
AlarmInfo.ALARM_FREQ_FLASH_FAULT : "闪存故障(CPF12)", # //109
AlarmInfo.ALARM_FREQ_MONITOR : "监视故障(CPF13)", # //110
AlarmInfo.ALARM_FREQ_CTRL_CIRCUIT : "控制回路故障(CPF14)", # //111
AlarmInfo.ALARM_FREQ_CLOCK_FAULT : "时钟故障(CPF16)", # //112
AlarmInfo.ALARM_FREQ_INTERRUPT_FAULT : "中断故障(CPF17)", # //113
AlarmInfo.ALARM_FREQ_PWM_FBDATA_ERR : "PWM 反馈数据异常(CPF23)", # //114
AlarmInfo.ALARM_FREQ_CAPACITY_SIGNAL : "变频器容量信号故障(CPF24)", # //115
AlarmInfo.ALARM_FREQ_TERMINAL_NOT_CONNECT : "未连接端子电路板(CPF25)", # //116
AlarmInfo.ALARM_FREQ_MONITOR_DEVICE : "监视装置故障(E5/CPF13)", # //117
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S1 : "外部故障(输入端子S1)(EF1)", # //118
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S2 : "外部故障(输入端子S2)(EF2)", # //119
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S3 : "外部故障(输入端子S3)(EF3)", # //120
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S4 : "外部故障(输入端子S4)(EF4)", # //121
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S5 : "外部故障(输入端子S5)(EF5)", # //122
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S6 : "外部故障(输入端子S6)(EF6)", # //123
AlarmInfo.ALARM_FREQ_EEPROMW_WRITE_ERR : "EEPROM 写入不当(Err)", # //124
AlarmInfo.ALARM_FREQ_PIDFB_OVERTOP : "PID 反馈超值(FbH)", # //125
AlarmInfo.ALARM_FREQ_PID_FB_LOST : "PID 反馈丧失(FbH)", # //126
AlarmInfo.ALARM_FREQ_GROUND_FALUT : "接地短路(GF)", # //127
AlarmInfo.ALARM_FREQ_OUT_PHASE_LOST : "输出缺相(LF)", # //128
AlarmInfo.ALARM_FREQ_OUT_IMBALANCE : "输出电流失衡(LF)", # //129
AlarmInfo.ALARM_FREQ_NODE_SETUP_ERR : "Node Setup 故障(LF)", # //130
AlarmInfo.ALARM_FREQ_OVER_CURRENT : "过电流(oC)", # //131
AlarmInfo.ALARM_FREQ_FIN_OVER_HEAT : "散热片过热(oH/oH1)", # //132
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT1 : "电机过热警告(PTC 输入)(oH3)", # //133
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT2 : "电机过热故障(PTC 输入)(oH4)", # //134
AlarmInfo.ALARM_FREQ_MOTOR_OVERLOAD : "电机过载(oL1)", # //135
AlarmInfo.ALARM_FREQ_VFD_OVERLOAD : "变频器过载(oL2)", # //136
AlarmInfo.ALARM_FREQ_OVER_TORQUE1 : "过转矩检出1(oL3)", # //137
AlarmInfo.ALARM_FREQ_OVER_TORQUE2 : "过转矩检出2(oL4)", # //138
AlarmInfo.ALARM_FREQ_MECHAN_AGING1 : "机械老化检出1(oL5)", # //139
AlarmInfo.ALARM_FREQ_BREAK_OVERLOAD : "高滑差制动电机过载保护(oL7)", # //140
AlarmInfo.ALARM_FREQ_OVER_VOLTAGE : "主回路过电压(ov)", # //141
AlarmInfo.ALARM_FREQ_VOLTAGE_FAULT : "主回路电压故障(PF)", # //142
AlarmInfo.ALARM_FREQ_BRAKE_TRANS : "内置制动晶体管故障(rr)", # //143
AlarmInfo.ALARM_FREQ_OUT_SHORT : "输出短路或IGBT故障(SC)", # //144
AlarmInfo.ALARM_FREQ_SPEED_SEARCH : "速度搜索重试故障(SC)", # //145
AlarmInfo.ALARM_FREQ_DISORDER : "失调检出(STo)", # //146
AlarmInfo.ALARM_FREQ_LACK_OF_TORQUE1 : "转矩不足1(UL3)", # //147
AlarmInfo.ALARM_FREQ_LACK_OF_TORQUE2 : "转矩不足2(UL4)", # //148
AlarmInfo.ALARM_FREQ_MECHAN_AGING2 : "机械老化检出2(UL5)", # //149
AlarmInfo.ALARM_FREQ_MAJOR_UNDERVOLTAGE : "主回路欠电压(Uv/Uv1)", # //150
AlarmInfo.ALARM_FREQ_CTRL_POW_FAULT : "控制电源故障(Uv2)", # //151
AlarmInfo.ALARM_FREQ_CONTROL1_ERR : "控制回路故障(CPF18)", # //151
AlarmInfo.ALARM_FREQ_CONTROL2_ERR : "控制回路故障(CPF19)", # //151
AlarmInfo.ALARM_FREQ_HARD1_ERR : "硬件故障(CPF20)", # //151
AlarmInfo.ALARM_FREQ_HARD2_ERR : "硬件故障(CPF21)", # //151
AlarmInfo.ALARM_FREQ_ADC_ERR : "ADC故障(CPF22)", # //151
AlarmInfo.ALARM_FREQ_PREVENT_SHOCK : "冲击防止回路故障(Uv3)", # //152
AlarmInfo.ALARM_FREQ_BASE_BLOCK : "变频器基极封锁(bb)", # //160
AlarmInfo.ALARM_FREQ_COMM_WAITING : "通信等待中(CALL)", # //161
AlarmInfo.ALARM_FREQ_RST_WHEN_RUN : "运行指令输入中复位(CrST)", # //162
AlarmInfo.ALARM_FREQ_COMM_CYCLE_ERR : "通信周期设定错误(CyC)", # //163
AlarmInfo.ALARM_FREQ_DRIVE_DISABLE : "Drive Disable中(dnE)", # //164
AlarmInfo.ALARM_FREQ_CW_CCW_CMD : "正反转指令同时输入(EF)", # //165: "
AlarmInfo.ALARM_FREQ_CURRENT_WARNING : "电流警告(HCA)", # //166
AlarmInfo.ALARM_FREQ_MAINTAIN_FAN : "冷却风扇维护时期(LT-1)", # //167
AlarmInfo.ALARM_FREQ_MAINTAIN_CAP : "电容器维护时期(LT-2)", # //168
AlarmInfo.ALARM_FREQ_MAINTAIN_RELAY : "冲击电流防止继电器维护时期(LT-3)", # //169
AlarmInfo.ALARM_FREQ_MAINTAIN_IGBT_50 : "IGBT维护时期(50%)(LT-4)", # //170
AlarmInfo.ALARM_FREQ_VFD_OH_ALERT : "变频器过热预警(oH2)", # //171
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT : "电机过热(oH3)", # //172
AlarmInfo.ALARM_FREQ_RSV173 : "保留", # //173
AlarmInfo.ALARM_FREQ_RSV174 : "保留", # //174
AlarmInfo.ALARM_FREQ_MOBUS_TEST_OK : "MEMOBUS通信测试模式正常(PASS)", # //175
AlarmInfo.ALARM_FREQ_SWITCH_WHEN_RUN : "运行中输入电机切换指令(rUn)", # //176
AlarmInfo.ALARM_FREQ_MOBUS_TEST_ERR : "MEMOBUS通信测试模式故障(SE)", # //177
AlarmInfo.ALARM_FREQ_MAINTAIN_IGBT_90 : "IGBT维护时期(90%)(TrPC)", # //178
AlarmInfo.ALARM_FREQ_RSV179 : "保留", # //179
AlarmInfo.ALARM_FREQ_RSV180 : "保留", # //180
AlarmInfo.ALARM_FREQ_CAPACITY_SET_ERR : "变频器容量的设定故障(oPE01)", # //181
AlarmInfo.ALARM_FREQ_CAPACITY_SET_ERR : "参数设定范围不当(oPE02)", # //182
AlarmInfo.ALARM_FREQ_DIN_SELECT_ERR : "多功能输入的选择不当(oPE03)", # //183
AlarmInfo.ALARM_FREQ_AIN_SELECT_ERR : "多功能模拟量输入的选择不当(oPE07)", # //184
AlarmInfo.ALARM_FREQ_PARA_SELECT_ERR : "参数选择不当(oPE08)", # //182
AlarmInfo.ALARM_FREQ_PID_SELECT_ERR : "PID控制的选择不当(oPE09)", # //183
AlarmInfo.ALARM_FREQ_VF_DATA_SET_ERR : "V/f数据的设定不当(oPE10)", # //184
AlarmInfo.ALARM_FREQ_CARRIER_SET_ERR : "载波频率的设定不当(oPE11)", # //182
AlarmInfo.USER_GLOBAL_ALARM_0 : "1#水箱液位低报警", #全局报警0",
AlarmInfo.USER_GLOBAL_ALARM_1 : "1#液位传感器未接入",
AlarmInfo.USER_GLOBAL_ALARM_2 : "2#液位传感器未接入",
AlarmInfo.USER_GLOBAL_ALARM_3 : "1#2#液位同时低",
AlarmInfo.USER_GLOBAL_ALARM_4 : "输入压力传感器无效",
AlarmInfo.USER_GLOBAL_ALARM_5 : "水箱无水同时进压低",
AlarmInfo.USER_GLOBAL_ALARM_6 : "全局报警6",
AlarmInfo.USER_GLOBAL_ALARM_7 : "全局报警7",
AlarmInfo.USER_GLOBAL_ALARM_8 : "全局报警8",
AlarmInfo.USER_GLOBAL_ALARM_9 : "全局报警9",
AlarmInfo.USER_GLOBAL_ALARM_10 : "全局报警10",
AlarmInfo.USER_GLOBAL_ALARM_11 : "全局报警11",
AlarmInfo.USER_GLOBAL_ALARM_12 : "全局报警12",
AlarmInfo.USER_GLOBAL_ALARM_13 : "全局报警13",
AlarmInfo.USER_GLOBAL_ALARM_14 : "全局报警14",
AlarmInfo.USER_GLOBAL_ALARM_15 : "全局报警15",
AlarmInfo.USER_GLOBAL_WARNING_0 : "1#水箱液位低警告",
AlarmInfo.USER_GLOBAL_WARNING_1 : "2#水箱液位低警告",
AlarmInfo.USER_GLOBAL_WARNING_2 : "全局警告2",
AlarmInfo.USER_GLOBAL_WARNING_3 : "全局警告3",
AlarmInfo.USER_GLOBAL_WARNING_4 : "全局警告4",
AlarmInfo.USER_GLOBAL_WARNING_5 : "全局警告5",
AlarmInfo.USER_GLOBAL_WARNING_6 : "全局警告6",
AlarmInfo.USER_GLOBAL_WARNING_7 : "全局警告7",
AlarmInfo.USER_GLOBAL_WARNING_8 : "全局警告8",
AlarmInfo.USER_GLOBAL_WARNING_9 : "全局警告9",
AlarmInfo.USER_GLOBAL_WARNING_10 : "全局警告10",
AlarmInfo.USER_GLOBAL_WARNING_11 : "全局警告11",
AlarmInfo.USER_GLOBAL_WARNING_12 : "全局警告12",
AlarmInfo.USER_GLOBAL_WARNING_13 : "全局警告13",
AlarmInfo.USER_GLOBAL_WARNING_14 : "全局警告14",
AlarmInfo.USER_GLOBAL_WARNING_15 : "全局警告15",
AlarmInfo.USER_LOCAL_WARNING_0 : "本机警告0",
AlarmInfo.USER_LOCAL_WARNING_1 : "本机警告1",
AlarmInfo.USER_LOCAL_WARNING_2 : "本机警告2",
AlarmInfo.USER_LOCAL_WARNING_3 : "本机警告3",
AlarmInfo.USER_LOCAL_WARNING_4 : "本机警告4",
AlarmInfo.USER_LOCAL_WARNING_5 : "本机警告5",
AlarmInfo.USER_LOCAL_WARNING_6 : "本机警告6",
AlarmInfo.USER_LOCAL_WARNING_7 : "本机警告7",
AlarmInfo.USER_LOCAL_WARNING_8 : "本机警告8",
AlarmInfo.USER_LOCAL_WARNING_9 : "本机警告9",
AlarmInfo.USER_LOCAL_WARNING_10 : "本机警告10",
AlarmInfo.USER_LOCAL_WARNING_11 : "本机警告11",
AlarmInfo.USER_LOCAL_WARNING_12 : "本机警告12",
AlarmInfo.USER_LOCAL_WARNING_13 : "本机警告13",
AlarmInfo.USER_LOCAL_WARNING_14 : "本机警告14",
AlarmInfo.USER_LOCAL_WARNING_15 : "本机警告15",
}},
{"alias_alarm_cause":
{
AlarmInfo.ALARM_FREE : "",
AlarmInfo.ALARM_PIPE_BROKE : "1. 系统管路泄漏@2. 输出压力传感器故障@3. 阀门开度太大",
AlarmInfo.ALARM_NO_WATER_EXIST : "1. 进水口无水或水压极低@2. 线路松动@3. 进水压力低于设定值@4. 模拟量异常或未校正,导到实系统压力值与实际压不一个致@5. 传感器故障",
AlarmInfo.ALARM_WATER_PRESSURE_HIGH : "1. 出水口水压过高@2. 线路松动@3. 电接点压力表设置不合理或故障4. 最低转速过高@5. 模拟量异常或未校正,导到系统压力值与实际压不一个致@6. 传感器故障",
AlarmInfo.ALARM_OVER_VOLTAGE : "1. 380V某一相(或几相)电压过高@2. 变频器故障",
AlarmInfo.ALARM_UNDER_VOLTAGE : "1. 380V某一相(或几相)电压过低@2. 变频器故障",
AlarmInfo.ALARM_BOARD_HARDWARE : "1. 需专业人员检修或更换控制器",
AlarmInfo.ALARM_IO_NO_WATER_EXIST : "1. 进水口无水或水箱浮球低位",
AlarmInfo.ALARM_SENSOR_PRESS_IN : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_PRESS_OUT : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_FLUX : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_PH : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_WATER_CLEAR : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_REMAIN_CL : STR_SensorFailCause,
AlarmInfo.ALARM_NEG_PRESSURE : "1. 进水口无水或水压极低@2. 线路松动@3. 进水压力低于设定值,@4. 模拟量异常或未校正,导到系统压力值与实际压不一个致@5. 传感器故障",
AlarmInfo.ALARM_VACUMM_PRESSURE : "1. 进水口无水或水压极低@2. 线路松动@3. 进水压力低于设定值,@4. 模拟量异常或未校正,导到实系统压力值与实际压不一个致@5. 传感器故障",
AlarmInfo.ALARM_SENSOR_WATER_LEVEL : STR_SensorFailCause,
AlarmInfo.ALARM_WATER_PRESSURE_LOW : "1. 并非故障,仅作提示@2. 电接点压力表低压设定值过大",
AlarmInfo.ALARM_SENSOR_FLUX_IN : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_IN_VALVE_FEEDBACK : "1. 调节阀故障@2. 模拟量口故障@3. 通信电缆的接线不正确,或发生短路、断线",
AlarmInfo.ALARM_SENSOR_NOIZE : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_HUMIDITY : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_WATER_LEVEL2 : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_IN_VALVE_FEEDBACK2 : STR_SensorFailCause,
AlarmInfo.ALARM_IO_LEAK_WATER : "1. 检测到漏水信号",
AlarmInfo.ALARM_IO_SMOKE : "1. 检测到烟感信号",
AlarmInfo.ALARM_IO_EXTERNALERROR : "1. 检测到外部故障信号",
AlarmInfo.ALARM_SENSOR_HUMIDITY : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_TEMPERATURE : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_TEMPERATURE2 : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_TEMPERATURE3 : STR_SensorFailCause,
AlarmInfo.ALARM_SENSOR_WATER_LEVEL3 : STR_SensorFailCause,
AlarmInfo.ALARM_COMM_FREQ_CONVERTER : "1. 通信电缆断线、接触不良@2. 通信参数不匹配@3. 受到干扰@4. 变频器型号选择错误",
AlarmInfo.ALARM_COMM_TOUCH_BOARD : EMPTY_STRING,
AlarmInfo.ALARM_COMM_MAIN_BOARD : "1. 线路松动、硬件故障、干扰",
AlarmInfo.ALARM_PUMP_AIR_SWITCH_OFF : EMPTY_STRING,
AlarmInfo.ALARM_MAIN_PUMP_LOST : "1. 未设置1号泵@2. 1号泵未上电@3. 1号泵已损坏@4.通信电缆的接线短路或断线@5.干扰导致通信数据发生故障",
AlarmInfo.ALARM_PUMP_RESET_DELAY : EMPTY_STRING,
AlarmInfo.ALARM_COMMAND_EXECUTE_FAIL : EMPTY_STRING,
AlarmInfo.ALARM_FREQ_PARAMETER_SET : EMPTY_STRING,
AlarmInfo.ALARM_PUMP_ADDR_ID_CONFLICT : "1. 设置了两台相同泵号",
AlarmInfo.ALARM_PUMP_MOTOR_TEMPERATURE_HIGH : "1. 冷却水量少@2. 电机故障",
AlarmInfo.ALARM_BUS_POWER_SHORT : "1. 通信电缆的接线不正确,或发生短路",
AlarmInfo.ALARM_POWER_LOST : "1. 380V电源未上电 ",
AlarmInfo.ALARM_FREQ_CURRENT_BASE : STR_FreqErrRef, #//电流偏置故障(CoF)", # //102
AlarmInfo.ALARM_FREQ_ADC_FAULT : STR_FreqErrRef, #//A/D 转换器故障(CPF02)", # //103
AlarmInfo.ALARM_FREQ_PWM_DATA_ERR : STR_FreqErrRef, #//PWM 数据异常(CPF03)", # //104
AlarmInfo.ALARM_FREQ_EEPROM_DATA_ERR : STR_FreqErrRef, #//EEPROM 数据异常(CPF06)", # //105
AlarmInfo.ALARM_FREQ_TERMINAL_FAULT : STR_FreqErrRef, #//端子电路板通信故障(CPF07)", # //106
AlarmInfo.ALARM_FREQ_EEPROM_COMM_FAULT : STR_FreqErrRef, #//EEPROM 串行通信故障(CPF08)", # //107
AlarmInfo.ALARM_FREQ_RAM_FAULT : STR_FreqErrRef, #//RAM 故障(CPF11)", # //108
AlarmInfo.ALARM_FREQ_FLASH_FAULT : STR_FreqErrRef, #//闪存故障(CPF12)", # //109
AlarmInfo.ALARM_FREQ_MONITOR : STR_FreqErrRef, #//监视故障(CPF13)", # //110
AlarmInfo.ALARM_FREQ_CTRL_CIRCUIT : STR_FreqErrRef, #//控制回路故障(CPF14)", # //111
AlarmInfo.ALARM_FREQ_CLOCK_FAULT : STR_FreqErrRef, #//时钟故障(CPF16)", # //112
AlarmInfo.ALARM_FREQ_INTERRUPT_FAULT : STR_FreqErrRef, #//中断故障(CPF17)", # //113
AlarmInfo.ALARM_FREQ_PWM_FBDATA_ERR : STR_FreqErrRef, #//PWM 反馈数据异常(CPF23)", # //114
AlarmInfo.ALARM_FREQ_CAPACITY_SIGNAL : STR_FreqErrRef, #//变频器容量信号故障(CPF24)", # //115
AlarmInfo.ALARM_FREQ_TERMINAL_NOT_CONNECT : STR_FreqErrRef, #//未连接端子电路板(CPF25)", # //116
AlarmInfo.ALARM_FREQ_MONITOR_DEVICE : STR_FreqErrRef, #//监视装置故障(E5/CPF13)", # //117
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S1 : STR_FreqErrRef, #//外部故障(输入端子S1)(EF1)", # //118
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S2 : STR_FreqErrRef, #//外部故障(输入端子S2)(EF2)", # //119
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S3 : STR_FreqErrRef, #//外部故障(输入端子S3)(EF3)", # //120
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S4 : STR_FreqErrRef, #//外部故障(输入端子S4)(EF4)", # //121
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S5 : STR_FreqErrRef, #//外部故障(输入端子S5)(EF5)", # //122
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S6 : STR_FreqErrRef, #//外部故障(输入端子S6)(EF6)", # //123
AlarmInfo.ALARM_FREQ_EEPROMW_WRITE_ERR : STR_FreqErrRef, #//EEPROM 写入不当(Err)", # //124
AlarmInfo.ALARM_FREQ_PIDFB_OVERTOP : STR_FreqErrRef, #//PID 反馈超值(FbH)", # //125
AlarmInfo.ALARM_FREQ_PID_FB_LOST : STR_FreqErrRef, #//PID 反馈丧失(FbH)", # //126
AlarmInfo.ALARM_FREQ_GROUND_FALUT : STR_FreqErrRef, #//接地短路(GF)", # //127
AlarmInfo.ALARM_FREQ_OUT_PHASE_LOST : STR_FreqErrRef, #//输出缺相(LF)", # //128
AlarmInfo.ALARM_FREQ_OUT_IMBALANCE : STR_FreqErrRef, #//输出电流失衡(LF)", # //129
AlarmInfo.ALARM_FREQ_NODE_SETUP_ERR : STR_FreqErrRef, #//Node Setup 故障(LF)", # //130
AlarmInfo.ALARM_FREQ_OVER_CURRENT : STR_FreqErrRef, #//过电流(oC)", # //131
AlarmInfo.ALARM_FREQ_FIN_OVER_HEAT : STR_FreqErrRef, #//散热片过热(oH/oH1)", # //132
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT1 : STR_FreqErrRef, #//电机过热警告(PTC 输入)(oH3)", # //133
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT2 : STR_FreqErrRef, #//电机过热故障(PTC 输入)(oH4)", # //134
AlarmInfo.ALARM_FREQ_MOTOR_OVERLOAD : STR_FreqErrRef, #//电机过载(oL1)", # //135
AlarmInfo.ALARM_FREQ_VFD_OVERLOAD : STR_FreqErrRef, #//变频器过载(oL2)", # //136
AlarmInfo.ALARM_FREQ_OVER_TORQUE1 : STR_FreqErrRef, #//过转矩检出1(oL3)", # //137
AlarmInfo.ALARM_FREQ_OVER_TORQUE2 : STR_FreqErrRef, #//过转矩检出2(oL4)", # //138
AlarmInfo.ALARM_FREQ_MECHAN_AGING1 : STR_FreqErrRef, #//机械老化检出1(oL5)", # //139
AlarmInfo.ALARM_FREQ_BREAK_OVERLOAD : STR_FreqErrRef, #//高滑差制动电机过载保护(oL7)", # //140
AlarmInfo.ALARM_FREQ_OVER_VOLTAGE : STR_FreqErrRef, #//主回路过电压(ov)", # //141
AlarmInfo.ALARM_FREQ_VOLTAGE_FAULT : STR_FreqErrRef, #//主回路电压故障(PF)", # //142
AlarmInfo.ALARM_FREQ_BRAKE_TRANS : STR_FreqErrRef, #//内置制动晶体管故障(rr)", # //143
AlarmInfo.ALARM_FREQ_OUT_SHORT : STR_FreqErrRef, #//输出短路或IGBT故障(SC)", # //144
AlarmInfo.ALARM_FREQ_SPEED_SEARCH : STR_FreqErrRef, #//速度搜索重试故障(SC)", # //145
AlarmInfo.ALARM_FREQ_DISORDER : STR_FreqErrRef, #//失调检出(STo)", # //146
AlarmInfo.ALARM_FREQ_LACK_OF_TORQUE1 : STR_FreqErrRef, #//转矩不足1(UL3)", # //147
AlarmInfo.ALARM_FREQ_LACK_OF_TORQUE2 : STR_FreqErrRef, #//转矩不足2(UL4)", # //148
AlarmInfo.ALARM_FREQ_MECHAN_AGING2 : STR_FreqErrRef, #//机械老化检出2(UL5)", # //149
AlarmInfo.ALARM_FREQ_MAJOR_UNDERVOLTAGE : STR_FreqErrRef, #//主回路欠电压(Uv/Uv1)", # //150
AlarmInfo.ALARM_FREQ_CTRL_POW_FAULT : STR_FreqErrRef, #//控制电源故障(Uv2)", # //151
AlarmInfo.ALARM_FREQ_CONTROL1_ERR : STR_FreqErrRef, #//控制回路故障(CPF18)", # //151
AlarmInfo.ALARM_FREQ_CONTROL2_ERR : STR_FreqErrRef, #//控制回路故障(CPF19)", # //151
AlarmInfo.ALARM_FREQ_HARD1_ERR : STR_FreqErrRef, #//硬件故障(CPF20)", # //151
AlarmInfo.ALARM_FREQ_HARD2_ERR : STR_FreqErrRef, #//硬件故障(CPF21)", # //151
AlarmInfo.ALARM_FREQ_ADC_ERR : STR_FreqErrRef, #//ADC故障(CPF22)", # //151
AlarmInfo.ALARM_FREQ_PREVENT_SHOCK : STR_FreqErrRef, #//冲击防止回路故障(Uv3)", # //152
AlarmInfo.ALARM_FREQ_BASE_BLOCK : STR_FreqErrRef, #//变频器基极封锁(bb)", # //160
AlarmInfo.ALARM_FREQ_COMM_WAITING : STR_FreqErrRef, #//通信等待中(CALL)", # //161
AlarmInfo.ALARM_FREQ_RST_WHEN_RUN : STR_FreqErrRef, #//运行指令输入中复位(CrST)", # //162
AlarmInfo.ALARM_FREQ_COMM_CYCLE_ERR : STR_FreqErrRef, #//通信周期设定错误(CyC)", # //163
AlarmInfo.ALARM_FREQ_DRIVE_DISABLE : STR_FreqErrRef, #//Drive Disable中(dnE)", # //164
AlarmInfo.ALARM_FREQ_CW_CCW_CMD : STR_FreqErrRef, #//正反转指令同时输入(EF)", # //165
AlarmInfo.ALARM_FREQ_CURRENT_WARNING : STR_FreqErrRef, #//电流警告(HCA)", # //166
AlarmInfo.ALARM_FREQ_MAINTAIN_FAN : STR_FreqErrRef, #//冷却风扇维护时期(LT-1)", # //167
AlarmInfo.ALARM_FREQ_MAINTAIN_CAP : STR_FreqErrRef, #//电容器维护时期(LT-2)", # //168
AlarmInfo.ALARM_FREQ_MAINTAIN_RELAY : STR_FreqErrRef, #//冲击电流防止继电器维护时期(LT-3)", # //169
AlarmInfo.ALARM_FREQ_MAINTAIN_IGBT_50 : STR_FreqErrRef, #//IGBT维护时期(50%)(LT-4)", # //170
AlarmInfo.ALARM_FREQ_VFD_OH_ALERT : STR_FreqErrRef, #//变频器过热预警(oH2)", # //171
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT : STR_FreqErrRef, #//电机过热(oH3)", # //172
AlarmInfo.ALARM_FREQ_RSV173 : STR_FreqErrRef, #//保留", # //173
AlarmInfo.ALARM_FREQ_RSV174 : STR_FreqErrRef, #//保留", # //174
AlarmInfo.ALARM_FREQ_MOBUS_TEST_OK : "正在进行通信测试", # //175
AlarmInfo.ALARM_FREQ_SWITCH_WHEN_RUN : STR_FreqErrRef, #//运行中输入电机切换指令(rUn)", # //176
AlarmInfo.ALARM_FREQ_MOBUS_TEST_ERR : STR_FreqErrRef, #//MEMOBUS通信测试模式故障(SE)", # //177
AlarmInfo.ALARM_FREQ_MAINTAIN_IGBT_90 : STR_FreqErrRef, #//IGBT维护时期(90%)(TrPC)", # //178
AlarmInfo.ALARM_FREQ_RSV179 : STR_FreqErrRef, #//保留", # //179
AlarmInfo.ALARM_FREQ_RSV180 : STR_FreqErrRef, #//保留", # //180
AlarmInfo.ALARM_FREQ_CAPACITY_SET_ERR : STR_FreqErrRef, #//变频器容量的设定故障(oPE01)", # //181
AlarmInfo.ALARM_FREQ_CAPACITY_SET_ERR : STR_FreqErrRef, #//参数设定范围不当(oPE02)", # //182
AlarmInfo.ALARM_FREQ_DIN_SELECT_ERR : STR_FreqErrRef, #//多功能输入的选择不当(oPE03)", # //183
AlarmInfo.ALARM_FREQ_AIN_SELECT_ERR : STR_FreqErrRef, #//多功能模拟量输入的选择不当(oPE07)", # //184
AlarmInfo.ALARM_FREQ_PARA_SELECT_ERR : STR_FreqErrRef, #//参数选择不当(oPE08)", # //182
AlarmInfo.ALARM_FREQ_PID_SELECT_ERR : STR_FreqErrRef, #//PID控制的选择不当(oPE09)", # //183
AlarmInfo.ALARM_FREQ_VF_DATA_SET_ERR : STR_FreqErrRef, #//V/f数据的设定不当(oPE10)", # //184
AlarmInfo.ALARM_FREQ_CARRIER_SET_ERR : STR_FreqErrRef, #//载波频率的设定不当(oPE11)", # //182
AlarmInfo.USER_GLOBAL_ALARM_0 : "1#水箱液位低于无水液位", #全局报警0",
AlarmInfo.USER_GLOBAL_ALARM_1 : "1#水箱无液位传感器输入",
AlarmInfo.USER_GLOBAL_ALARM_2 : "2#水箱无液位传感器输入",
AlarmInfo.USER_GLOBAL_ALARM_3 : "1#水箱液位低, 2#水箱液位低",
AlarmInfo.USER_GLOBAL_ALARM_4 : "输入压力传感器未配置或损坏",
AlarmInfo.USER_GLOBAL_ALARM_5 : "1.水箱液位低于无水液位@2. 同时进水压力低于进压关阀压力 ",
AlarmInfo.USER_GLOBAL_ALARM_6 : "全局报警6",
AlarmInfo.USER_GLOBAL_ALARM_7 : "全局报警7",
AlarmInfo.USER_GLOBAL_ALARM_8 : "全局报警8",
AlarmInfo.USER_GLOBAL_ALARM_9 : "全局报警9",
AlarmInfo.USER_GLOBAL_ALARM_10 : "全局报警10",
AlarmInfo.USER_GLOBAL_ALARM_11 : "全局报警11",
AlarmInfo.USER_GLOBAL_ALARM_12 : "全局报警12",
AlarmInfo.USER_GLOBAL_ALARM_13 : "全局报警13",
AlarmInfo.USER_GLOBAL_ALARM_14 : "全局报警14",
AlarmInfo.USER_GLOBAL_ALARM_15 : "全局报警15",
AlarmInfo.USER_GLOBAL_WARNING_0 : "1#水箱液位低于无水液位",
AlarmInfo.USER_GLOBAL_WARNING_1 : "2#水箱液位低于无水液位",
AlarmInfo.USER_GLOBAL_WARNING_2 : "全局警告2",
AlarmInfo.USER_GLOBAL_WARNING_3 : "全局警告3",
AlarmInfo.USER_GLOBAL_WARNING_4 : "全局警告4",
AlarmInfo.USER_GLOBAL_WARNING_5 : "全局警告5",
AlarmInfo.USER_GLOBAL_WARNING_6 : "全局警告6",
AlarmInfo.USER_GLOBAL_WARNING_7 : "全局警告7",
AlarmInfo.USER_GLOBAL_WARNING_8 : "全局警告8",
AlarmInfo.USER_GLOBAL_WARNING_9 : "全局警告9",
AlarmInfo.USER_GLOBAL_WARNING_10 : "全局警告10",
AlarmInfo.USER_GLOBAL_WARNING_11 : "全局警告11",
AlarmInfo.USER_GLOBAL_WARNING_12 : "全局警告12",
AlarmInfo.USER_GLOBAL_WARNING_13 : "全局警告13",
AlarmInfo.USER_GLOBAL_WARNING_14 : "全局警告14",
AlarmInfo.USER_GLOBAL_WARNING_15 : "全局警告15",
}},
{"alias_alarm_help":
{
AlarmInfo.ALARM_FREE : "",
AlarmInfo.ALARM_PIPE_BROKE : "1. 管路修复@2. 检查传感器线路及更换传感器@3. 配置更大流量的泵或减少阀门开度",
AlarmInfo.ALARM_NO_WATER_EXIST : "1. 有水后自动解除故障@2. 检查传感器线路@3. @4. 出水压力显示是否正常,进行参数校正@5. 检查进水压力传感器是否正常",
AlarmInfo.ALARM_WATER_PRESSURE_HIGH : "1. 水压降低后自动解除@2. 检查传感器线路@3. 检查出水电接点压力表是否正常。n\4. 变频器最小频率是否合理。@5. 出水压力显示是否正常,进行参数校正@6. 出水传感器是否正常。",
AlarmInfo.ALARM_OVER_VOLTAGE : "1. 检查380V三相电压@2. 更换变频器",
AlarmInfo.ALARM_UNDER_VOLTAGE : "1. 检查380V三相电压@2. 更换变频器",
AlarmInfo.ALARM_BOARD_HARDWARE : "1. 更换电机",
AlarmInfo.ALARM_IO_NO_WATER_EXIST : "1. 有水后自动解除故障 @2检查无水信号IO点 @3检查水箱液位传感器",
AlarmInfo.ALARM_SENSOR_PRESS_IN : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_PRESS_OUT : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_FLUX : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_PH : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_WATER_CLEAR : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_REMAIN_CL : STR_SensorFailProcess,
AlarmInfo.ALARM_NEG_PRESSURE : "1. 有水后自动解除故障@2. 检查传感器线路@3. 检查设置是否合理,@4. 出水压力显示是否正常,进行参数校正@5. 检查进水压力传感器是否正常",
AlarmInfo.ALARM_VACUMM_PRESSURE : "1. 有水后自动解除故障@2. 检查传感器线路@3. 检查设置是否合理,@4. 出水压力显示是否正常,进行参数校正@5. 检查进水压力传感器是否正常",
AlarmInfo.ALARM_SENSOR_WATER_LEVEL : STR_SensorFailProcess,
AlarmInfo.ALARM_WATER_PRESSURE_LOW : "1. 无需处理@2. 检查电接点压力表设定值",
AlarmInfo.ALARM_SENSOR_FLUX_IN : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_IN_VALVE_FEEDBACK : "1. 更换调节阀@2. 更换电机@3. 检查调节阀是否断线或损坏。",
AlarmInfo.ALARM_SENSOR_NOIZE : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_HUMIDITY : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_WATER_LEVEL2 : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_IN_VALVE_FEEDBACK2 : STR_SensorFailProcess,
AlarmInfo.ALARM_IO_LEAK_WATER : "1. 漏水信号消除后自动解除故障",
AlarmInfo.ALARM_IO_SMOKE : "1. 烟感信号消除后自动解除故障",
AlarmInfo.ALARM_IO_EXTERNALERROR : "1. 外部故障信号消除后自动解除故障",
AlarmInfo.ALARM_SENSOR_HUMIDITY : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_TEMPERATURE : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_TEMPERATURE2 : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_TEMPERATURE3 : STR_SensorFailProcess,
AlarmInfo.ALARM_SENSOR_WATER_LEVEL3 : STR_SensorFailProcess,
AlarmInfo.ALARM_COMM_FREQ_CONVERTER : "1. 检查通信电缆和接线@2. 检查波特率等通信参数的设置@3. 排除干扰,详见说明书@4. 修改 系统信息>变频器型号",
AlarmInfo.ALARM_COMM_TOUCH_BOARD : EMPTY_STRING,
AlarmInfo.ALARM_COMM_MAIN_BOARD : "1. 检查是否存在干扰现象。",
AlarmInfo.ALARM_PUMP_AIR_SWITCH_OFF : EMPTY_STRING,
AlarmInfo.ALARM_MAIN_PUMP_LOST : "1. 设置一台水泵为1号泵@2. 检查电源@3. 把原1号泵断开连接, 重新设置一台1号泵@4. 检查CAN通讯线束@5. 确认抗干扰对策的状况。@6. 检查控制回路的接线、主回路接地线",
AlarmInfo.ALARM_PUMP_RESET_DELAY : EMPTY_STRING,
AlarmInfo.ALARM_COMMAND_EXECUTE_FAIL : EMPTY_STRING,
AlarmInfo.ALARM_FREQ_PARAMETER_SET : EMPTY_STRING,
AlarmInfo.ALARM_PUMP_ADDR_ID_CONFLICT : "1. 检查泵号设置",
AlarmInfo.ALARM_PUMP_MOTOR_TEMPERATURE_HIGH : "1. 调整减压阀,加大冷却水流量@2. 清洗减压阀过滤网@3. 更换电机",
AlarmInfo.ALARM_BUS_POWER_SHORT : "1. 检查CAN通讯线束",
AlarmInfo.ALARM_POWER_LOST : "1. 检查380V电源是否打开@2.检查线路是否松动",
AlarmInfo.ALARM_FREQ_CURRENT_BASE : STR_FreqErrRef, #//电流偏置故障(CoF)", # //102
AlarmInfo.ALARM_FREQ_ADC_FAULT : STR_FreqErrRef, #//A/D 转换器故障(CPF02)", # //103
AlarmInfo.ALARM_FREQ_PWM_DATA_ERR : STR_FreqErrRef, #//PWM 数据异常(CPF03)", # //104
AlarmInfo.ALARM_FREQ_EEPROM_DATA_ERR : STR_FreqErrRef, #//EEPROM 数据异常(CPF06)", # //105
AlarmInfo.ALARM_FREQ_TERMINAL_FAULT : STR_FreqErrRef, #//端子电路板通信故障(CPF07)", # //106
AlarmInfo.ALARM_FREQ_EEPROM_COMM_FAULT : STR_FreqErrRef, #//EEPROM 串行通信故障(CPF08)", # //107
AlarmInfo.ALARM_FREQ_RAM_FAULT : STR_FreqErrRef, #//RAM 故障(CPF11)", # //108
AlarmInfo.ALARM_FREQ_FLASH_FAULT : STR_FreqErrRef, #//闪存故障(CPF12)", # //109
AlarmInfo.ALARM_FREQ_MONITOR : STR_FreqErrRef, #//监视故障(CPF13)", # //110
AlarmInfo.ALARM_FREQ_CTRL_CIRCUIT : STR_FreqErrRef, #//控制回路故障(CPF14)", # //111
AlarmInfo.ALARM_FREQ_CLOCK_FAULT : STR_FreqErrRef, #//时钟故障(CPF16)", # //112
AlarmInfo.ALARM_FREQ_INTERRUPT_FAULT : STR_FreqErrRef, #//中断故障(CPF17)", # //113
AlarmInfo.ALARM_FREQ_PWM_FBDATA_ERR : STR_FreqErrRef, #//PWM 反馈数据异常(CPF23)", # //114
AlarmInfo.ALARM_FREQ_CAPACITY_SIGNAL : STR_FreqErrRef, #//变频器容量信号故障(CPF24)", # //115
AlarmInfo.ALARM_FREQ_TERMINAL_NOT_CONNECT : STR_FreqErrRef, #//未连接端子电路板(CPF25)", # //116
AlarmInfo.ALARM_FREQ_MONITOR_DEVICE : STR_FreqErrRef, #//监视装置故障(E5/CPF13)", # //117
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S1 : STR_FreqErrRef, #//外部故障(输入端子S1)(EF1)", # //118
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S2 : STR_FreqErrRef, #//外部故障(输入端子S2)(EF2)", # //119
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S3 : STR_FreqErrRef, #//外部故障(输入端子S3)(EF3)", # //120
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S4 : STR_FreqErrRef, #//外部故障(输入端子S4)(EF4)", # //121
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S5 : STR_FreqErrRef, #//外部故障(输入端子S5)(EF5)", # //122
AlarmInfo.ALARM_FREQ_EXTERN_FAULT_S6 : STR_FreqErrRef, #//外部故障(输入端子S6)(EF6)", # //123
AlarmInfo.ALARM_FREQ_EEPROMW_WRITE_ERR : STR_FreqErrRef, #//EEPROM 写入不当(Err)", # //124
AlarmInfo.ALARM_FREQ_PIDFB_OVERTOP : STR_FreqErrRef, #//PID 反馈超值(FbH)", # //125
AlarmInfo.ALARM_FREQ_PID_FB_LOST : STR_FreqErrRef, #//PID 反馈丧失(FbH)", # //126
AlarmInfo.ALARM_FREQ_GROUND_FALUT : STR_FreqErrRef, #//接地短路(GF)", # //127
AlarmInfo.ALARM_FREQ_OUT_PHASE_LOST : STR_FreqErrRef, #//输出缺相(LF)", # //128
AlarmInfo.ALARM_FREQ_OUT_IMBALANCE : STR_FreqErrRef, #//输出电流失衡(LF)", # //129
AlarmInfo.ALARM_FREQ_NODE_SETUP_ERR : STR_FreqErrRef, #//Node Setup 故障(LF)", # //130
AlarmInfo.ALARM_FREQ_OVER_CURRENT : STR_FreqErrRef, #//过电流(oC)", # //131
AlarmInfo.ALARM_FREQ_FIN_OVER_HEAT : STR_FreqErrRef, #//散热片过热(oH/oH1)", # //132
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT1 : STR_FreqErrRef, #//电机过热警告(PTC 输入)(oH3)", # //133
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT2 : STR_FreqErrRef, #//电机过热故障(PTC 输入)(oH4)", # //134
AlarmInfo.ALARM_FREQ_MOTOR_OVERLOAD : STR_FreqErrRef, #//电机过载(oL1)", # //135
AlarmInfo.ALARM_FREQ_VFD_OVERLOAD : STR_FreqErrRef, #//变频器过载(oL2)", # //136
AlarmInfo.ALARM_FREQ_OVER_TORQUE1 : STR_FreqErrRef, #//过转矩检出1(oL3)", # //137
AlarmInfo.ALARM_FREQ_OVER_TORQUE2 : STR_FreqErrRef, #//过转矩检出2(oL4)", # //138
AlarmInfo.ALARM_FREQ_MECHAN_AGING1 : STR_FreqErrRef, #//机械老化检出1(oL5)", # //139
AlarmInfo.ALARM_FREQ_BREAK_OVERLOAD : STR_FreqErrRef, #//高滑差制动电机过载保护(oL7)", # //140
AlarmInfo.ALARM_FREQ_OVER_VOLTAGE : STR_FreqErrRef, #//主回路过电压(ov)", # //141
AlarmInfo.ALARM_FREQ_VOLTAGE_FAULT : STR_FreqErrRef, #//主回路电压故障(PF)", # //142
AlarmInfo.ALARM_FREQ_BRAKE_TRANS : STR_FreqErrRef, #//内置制动晶体管故障(rr)", # //143
AlarmInfo.ALARM_FREQ_OUT_SHORT : STR_FreqErrRef, #//输出短路或IGBT故障(SC)", # //144
AlarmInfo.ALARM_FREQ_SPEED_SEARCH : STR_FreqErrRef, #//速度搜索重试故障(SC)", # //145
AlarmInfo.ALARM_FREQ_DISORDER : STR_FreqErrRef, #//失调检出(STo)", # //146
AlarmInfo.ALARM_FREQ_LACK_OF_TORQUE1 : STR_FreqErrRef, #//转矩不足1(UL3)", # //147
AlarmInfo.ALARM_FREQ_LACK_OF_TORQUE2 : STR_FreqErrRef, #//转矩不足2(UL4)", # //148
AlarmInfo.ALARM_FREQ_MECHAN_AGING2 : STR_FreqErrRef, #//机械老化检出2(UL5)", # //149
AlarmInfo.ALARM_FREQ_MAJOR_UNDERVOLTAGE : STR_FreqErrRef, #//主回路欠电压(Uv/Uv1)", # //150
AlarmInfo.ALARM_FREQ_CTRL_POW_FAULT : STR_FreqErrRef, #//控制电源故障(Uv2)", # //151
AlarmInfo.ALARM_FREQ_CONTROL1_ERR : STR_FreqErrRef, #//控制回路故障(CPF18)", # //151
AlarmInfo.ALARM_FREQ_CONTROL2_ERR : STR_FreqErrRef, #//控制回路故障(CPF19)", # //151
AlarmInfo.ALARM_FREQ_HARD1_ERR : STR_FreqErrRef, #//硬件故障(CPF20)", # //151
AlarmInfo.ALARM_FREQ_HARD2_ERR : STR_FreqErrRef, #//硬件故障(CPF21)", # //151
AlarmInfo.ALARM_FREQ_ADC_ERR : STR_FreqErrRef, #//ADC故障(CPF22)", # //151
AlarmInfo.ALARM_FREQ_PREVENT_SHOCK : STR_FreqErrRef, #//冲击防止回路故障(Uv3)", # //152
AlarmInfo.ALARM_FREQ_BASE_BLOCK : STR_FreqErrRef, #//变频器基极封锁(bb)", # //160
AlarmInfo.ALARM_FREQ_COMM_WAITING : STR_FreqErrRef, #//通信等待中(CALL)", # //161
AlarmInfo.ALARM_FREQ_RST_WHEN_RUN : STR_FreqErrRef, #//运行指令输入中复位(CrST)", # //162
AlarmInfo.ALARM_FREQ_COMM_CYCLE_ERR : STR_FreqErrRef, #//通信周期设定错误(CyC)", # //163
AlarmInfo.ALARM_FREQ_DRIVE_DISABLE : STR_FreqErrRef, #//Drive Disable中(dnE)", # //164
AlarmInfo.ALARM_FREQ_CW_CCW_CMD : STR_FreqErrRef, #//正反转指令同时输入(EF)", # //165
AlarmInfo.ALARM_FREQ_CURRENT_WARNING : STR_FreqErrRef, #//电流警告(HCA)", # //166
AlarmInfo.ALARM_FREQ_MAINTAIN_FAN : STR_FreqErrRef, #//冷却风扇维护时期(LT-1)", # //167
AlarmInfo.ALARM_FREQ_MAINTAIN_CAP : STR_FreqErrRef, #//电容器维护时期(LT-2)", # //168
AlarmInfo.ALARM_FREQ_MAINTAIN_RELAY : STR_FreqErrRef, #//冲击电流防止继电器维护时期(LT-3)", # //169
AlarmInfo.ALARM_FREQ_MAINTAIN_IGBT_50 : STR_FreqErrRef, #//IGBT维护时期(50%)(LT-4)", # //170
AlarmInfo.ALARM_FREQ_VFD_OH_ALERT : STR_FreqErrRef, #//变频器过热预警(oH2)", # //171
AlarmInfo.ALARM_FREQ_MOTOR_OVERHEAT : STR_FreqErrRef, #//电机过热(oH3)", # //172
AlarmInfo.ALARM_FREQ_RSV173 : STR_FreqErrRef, #//保留", # //173
AlarmInfo.ALARM_FREQ_RSV174 : STR_FreqErrRef, #//保留", # //174
AlarmInfo.ALARM_FREQ_MOBUS_TEST_OK : "不必采取对策(并非警报)", # //175
AlarmInfo.ALARM_FREQ_SWITCH_WHEN_RUN : STR_FreqErrRef, #//运行中输入电机切换指令(rUn)", # //176
AlarmInfo.ALARM_FREQ_MOBUS_TEST_ERR : STR_FreqErrRef, #//MEMOBUS通信测试模式故障(SE)", # //177
AlarmInfo.ALARM_FREQ_MAINTAIN_IGBT_90 : STR_FreqErrRef, #//IGBT维护时期(90%)(TrPC)", # //178
AlarmInfo.ALARM_FREQ_RSV179 : STR_FreqErrRef, #//保留", # //179
AlarmInfo.ALARM_FREQ_RSV180 : STR_FreqErrRef, #//保留", # //180
AlarmInfo.ALARM_FREQ_CAPACITY_SET_ERR : STR_FreqErrRef, #//变频器容量的设定故障(oPE01)", # //181
AlarmInfo.ALARM_FREQ_CAPACITY_SET_ERR : STR_FreqErrRef, #//参数设定范围不当(oPE02)", # //182
AlarmInfo.ALARM_FREQ_DIN_SELECT_ERR : STR_FreqErrRef, #//多功能输入的选择不当(oPE03)", # //183
AlarmInfo.ALARM_FREQ_AIN_SELECT_ERR : STR_FreqErrRef, #//多功能模拟量输入的选择不当(oPE07)", # //184
AlarmInfo.ALARM_FREQ_PARA_SELECT_ERR : STR_FreqErrRef, #//参数选择不当(oPE08)", # //182
AlarmInfo.ALARM_FREQ_PID_SELECT_ERR : STR_FreqErrRef, #//PID控制的选择不当(oPE09)", # //183
AlarmInfo.ALARM_FREQ_VF_DATA_SET_ERR : STR_FreqErrRef, #//V/f数据的设定不当(oPE10)", # //184
AlarmInfo.ALARM_FREQ_CARRIER_SET_ERR : STR_FreqErrRef, #//载波频率的设定不当(oPE11)", # //182
AlarmInfo.USER_GLOBAL_ALARM_0 : "1. PLC程序跳到非水箱程序@2. 调整水箱液位无水配置@3. 检测水箱是否真的无水@4. 水箱加水",
AlarmInfo.USER_GLOBAL_ALARM_1 : "1. 检查1#水箱的液位状态",
AlarmInfo.USER_GLOBAL_ALARM_2 : "1. 检查2#水箱的液位状态",
AlarmInfo.USER_GLOBAL_ALARM_3 : "1. 同时检查两个水箱的液位状态@2. 更换水箱液位传感器@3. 检查水箱进水阀",
AlarmInfo.USER_GLOBAL_ALARM_4 : "1. 检查或更换输入压力传感器 @2. 正确配置输入压力传感器",
AlarmInfo.USER_GLOBAL_ALARM_5 : "1. 检查水箱液位与进水压力 @2. 等待进水压力超过开阀压力",
AlarmInfo.USER_GLOBAL_ALARM_6 : "全局报警6",
AlarmInfo.USER_GLOBAL_ALARM_7 : "全局报警7",
AlarmInfo.USER_GLOBAL_ALARM_8 : "全局报警8",
AlarmInfo.USER_GLOBAL_ALARM_9 : "全局报警9",
AlarmInfo.USER_GLOBAL_ALARM_10 : "全局报警10",
AlarmInfo.USER_GLOBAL_ALARM_11 : "全局报警11",
AlarmInfo.USER_GLOBAL_ALARM_12 : "全局报警12",
AlarmInfo.USER_GLOBAL_ALARM_13 : "全局报警13",
AlarmInfo.USER_GLOBAL_ALARM_14 : "全局报警14",
AlarmInfo.USER_GLOBAL_ALARM_15 : "全局报警15",
AlarmInfo.USER_GLOBAL_WARNING_0 : "检查1#水箱液位情况",
AlarmInfo.USER_GLOBAL_WARNING_1 : "检查2#水箱液位情况",
AlarmInfo.USER_GLOBAL_WARNING_2 : "全局警告2",
AlarmInfo.USER_GLOBAL_WARNING_3 : "全局警告3",
AlarmInfo.USER_GLOBAL_WARNING_4 : "全局警告4",
AlarmInfo.USER_GLOBAL_WARNING_5 : "全局警告5",
AlarmInfo.USER_GLOBAL_WARNING_6 : "全局警告6",
AlarmInfo.USER_GLOBAL_WARNING_7 : "全局警告7",
AlarmInfo.USER_GLOBAL_WARNING_8 : "全局警告8",
AlarmInfo.USER_GLOBAL_WARNING_9 : "全局警告9",
AlarmInfo.USER_GLOBAL_WARNING_10 : "全局警告10",
AlarmInfo.USER_GLOBAL_WARNING_11 : "全局警告11",
AlarmInfo.USER_GLOBAL_WARNING_12 : "全局警告12",
AlarmInfo.USER_GLOBAL_WARNING_13 : "全局警告13",
AlarmInfo.USER_GLOBAL_WARNING_14 : "全局警告14",
AlarmInfo.USER_GLOBAL_WARNING_15 : "全局警告15",
}},
#模拟量输入固定为第0项
{"alias_aiinput": {0: "保留",
1:"输出压力",
2:"输入压力",
3:"液位信号",
4:"调节阀反馈",
5:"输出流量",
6:"温度",
7:"余氯信息",
8:"浊度信息",
9:"PH信息",
10:"输入流量",
11:"保留11",
12:"保留12",
13:"PAI0",
14:"PAI1",
15:"夹层温度",
16:"站内温度",
17:"开度反馈2",
18:"液位2",
19:"噪音",
20:"湿度",
21:"液位3",
}},
{"alias_user_alarm": {0:"关闭", 1:"打开"}},
{"alias_bool": {0:"关闭", 1:"打开"}},
{"alias_voltage": {0:"380V", 1:"660V", 2:"1140V"}},
{"alias_converter": {0: "V1000", 1: "MD380", 2: "S3100A",3: "MD80", 4: "WIDM100"}},
{"alias_parity": {0: "无校验", 1: "奇校验", 2: "偶校验"}},
{"alias_485stop": {0: "1", 1: "2"}},
{"alias_baud": {0: "1200", 1: "2400", 2: "4800", 3: "9600", 4:"19200", 5:"38400", 6:"51200", 7:"115200"}},
{"alias_can_baud": {0: "1M", 1: "800K", 2: "500K", 3: "250K", 4:"125K", 5:"100K", 6:"50K", 7:"20K", 8:"10K"}},
{"alias_NoNC": {0: "常开", 1: "常闭"}},
{"alias_bluetooth": {0: "未连接", 1: "连接"}},
{"alias_onoff": {0: "分闸", 1: "合闸"}},
{"alias_alarm": {0: "无故障", 1: "定时限短路", 2 : "定时限过流1段", 3: "定时限过流2段"}},
{"alias_test": {0: "测试", 1: "动作"}},
{"alias_workmode2": {0: "手动", 1: "自动"}},
{"alias_comm": {0: "保留", 1: "脚本", 2: "调试"}},
{"alias_priority": {0: "相等优先级", 1: "主泵优先", 2: "辅泵优先"}},
{"alias_pidmode": {0: "自定义", 1: "轻载", 2: "中载", 3: "重载"}},
{"alias_pid": {0: "NULL", 1: "P", 2: "I", 3: "PI", 4: "D", 5: "PD", 6: "ID", 7: "PID"}},
{"alias_language": {0: "中文", 1: "英文"}},
{"alias_PX": {0: "正常", 1: "关闭"}},
{"alias_devicestatus": {0: "本地停止", 1: "本地自动", 2: "远程控制", 3: "远程急停"}},
{"alias_alarmstatus": {0: "正常", 1: "报警"}},
{"alias_Energymeter": {0: "0-停用", 1: "1-安科瑞电表", 2: "2-斯菲尔电表"}},
{"alias_plc": {0:"0-调试程序",
1:"1-调峰程序",
2:"2-GPRS+流量计",
3:"3-双水箱",
4:"4-箱式无负压",
5:"5-爆管阀门控制",
6:"6-单水箱",
7:"7-翰林国际小区",
8:"8-兼容全功能",
9:"9-楼顶水箱",
10: "10-保留",
11: "11-保留"}},
{"alias_plc_pin": {0:"0-保留脚位",
1:"1-初始脚位",
2:"2-GPRS+流量计",
3:"3-双水箱脚位",
4:"4-箱式无负压脚位",
5:"5-爆管阀门脚位",
6:"6-单水箱脚位",
7:"7-翰林国际小区脚位",
8:"8-兼容全功能脚位",
9:"9-楼顶水箱脚位",
10: "10-保留脚位",
11: "11-保留脚位"}},
{"alias_aioutput": {0:"保留",
1:"市政水箱切换阀",
2:"1#水箱补水阀",
3:"2#水箱补水阀",
4:"1#水箱出水阀",
5:"3#水箱补水阀",
}},
{"alias_input": {0:"未使用",
1:"电接点压力低",
2:"电接点压力高",
3:"市政无水信号",
4:"1#浮球无水",
7:"漏水信号",
8:"烟感信号",
9:"外部故障",
10:"2#浮球无水",
11:"门禁信号",
12:"无水信号常闭",
24:"1#浮球高位", #M163.0
25:"1#开阀到位", #M163.1
26:"1#关阀到位", #M163.2
27:"1#阀门故障信号", #M163.3
28:"1#浮球低位", #M163.4
32:"2#浮球高位", #M164.0
33:"2#开阀到位", #m164.1
34:"2#关阀到位", #M164.2
35:"2#阀门故障信号", #M164.3
36:"2#浮球低位", #M164.4
38:"爆管开阀到位",
39:"爆管关阀到位",
43:"进压开阀到位",
44:"进压关阀到位",
47:"切换开阀到位",
48:"切换关阀到位",
49:"3#浮球高位",
50:"3#开阀到位",
51:"3#关阀到位",
52:"3#阀门故障信号",
53:"3#楼顶浮球低",
54:"1#楼顶浮球低",
55:"2#楼顶浮球低"}},
{"alias_output": {0:"未使用",
17: "Y0.0",
18: "Y0.1",
20: "Y0.3",
29 : "1#水箱开阀",
30:"1#水箱关阀",
31: "2#水箱开阀",
32: "2#水箱关阀",
33: "爆管开阀",
34:"爆管关阀",
35:"进压开阀",
36:"进压关阀",
37: "风机开关",
38: "加热开关",
39:"空调开关",
40:"切换装置开阀",
41: "切换装置关阀",
42: "照明开关",
43: "开门输出",
44:"关门输出",
45:"紫外消毒输出",
46: "3#水箱开阀",
47: "3#水箱关阀"}},
{"alias_temp_wet": {0:"0-停用",
1:"1-RS_WS_N01"}},
{"alias_noise": {0:"0-停用",
1:"1-RS-ZS-N01"}},
{"alias_flowmeter": {0:"0-停用",
1:"1-迪纳声流量计",
2:"2-熊猫PWM流量计",
3:"3-科龙IFC300流量计",
4:"4-星空XKD99Z流量计",
5:"5-熊猫PMF流量计",
6:"6-户表流量计"}},
{"alias_waterquality": {0:"0-停用", 1:"1-天健TMS3000"}},
{"alias_tempmiddle": {0:"0-停用", 1:"1-壁挂王字壳"}},
{"alias_valve_output" : {0: "未动作", 1: "开阀输出", 2: "关阀输出"}},
{"alias_valve_status" : {0: "未到位", 1: "已到位"}},
{"alias_run_function" : {0: "关闭", 1: "自动", 2: "手动"}},
{"alias_PumpName" : {0: "1号泵", 1: "2号泵", 2: "3号泵", 3: "4号泵", 4: "5号泵", 5: "6号泵", 6: "7号泵", 7: "8号泵"}},
{"alias_anaolog_mode": {0:"4-20mA", 1:"0-10V"}},
{"alias_pressure_in_select": {0: "市政输入", 1: "水箱输入"}}
]
def func_comm_switch_on(object_device : class_comm_device, topic_item, topic, message) :
object_list = object_device.parent
value = 1
result = object_list.comm_single_bit_write(object_device.comm_addr, 618, 1, value)
return result
def func_comm_switch_off(object_device, topic_item, topic, message) :
object_list = object_device.parent
value = 1
result = object_list.comm_single_bit_write(object_device.comm_addr, 619, 1, value)
return result
def func_comm_switch_rst(object_device, topic_item, topic, message) :
object_list = object_device.parent
value = 1
result = object_list.comm_single_bit_write(object_device.comm_addr, 620, 1, value)
return result
def func_comm_test_leak(object_device, topic_item, topic, message) :
return None
#mqtt 执行的开关命令, 可通过远程发送该命令
mqtt_topic_subscribe = [
{"name": "通讯分闸", "execute": func_comm_switch_on},
{"name": "通讯合闸", "execute": func_comm_switch_off},
{"name": "故障复位", "execute": func_comm_switch_rst},
{"name": "漏电试验", "execute": func_comm_test_leak},
]
mqtt_pack_alarm = [
{
"name": "AlarmType",
"addr": "8138",
"alias": "alias_test"
},
]
dynamic_page_main = [
{
"name": "进水压力",
"unit": "Mpa",
"scale" : 0.001,
"addr": "40023",
"format": "%05.2f",
},
{
"name": "水箱液位",
"unit": "m",
"scale" : 0.01,
"addr": "40029",
"format": "%05.2f",
},
{
"name": "实际压力",
"unit": "Mpa",
"scale" : 0.001,
"addr": "40025",
"format": "%05.2f",
},
{
"name": "设定压力",
"unit": "Mpa",
"scale" : 0.001,
"addr": "40416",
"format": "%05.2f",
},
{
"name": "工作电流",
"unit": "A",
"scale" : 0.1,
"addr": "40049",
"format": "%04.1f",
},
{
"name": "瞬时功率",
"unit": "kW",
"scale" : 0.1,
"addr": "40007",
"format": "%04.1f",
},
]
modbus_comm_table = [
{"name":"status", "reg_addr":8162, "reg_count":4, "cycle": 100},
{"name":"alarm", "reg_addr":8120, "reg_count":10, "cycle": 0, "mqtt_pack": "mqtt_pack_alarm"},
{"name":"measure", "reg_addr":8139, "reg_count":35, "cycle": 200, "mqtt_pack": "dynamic_page_main"},
{"name":"comm_cmd", "reg_addr":100618, "reg_count":32, "cycle": 0},
{"name":"para_group", "reg_addr":2000, "reg_count":10, "cycle": 0},
{"name":"time_group", "reg_addr":2300, "reg_count":6, "cycle": 500},
{"name":"protect_group", "reg_addr":8174, "reg_count":26, "cycle": 0},
{"name":"ip_addr_group", "reg_addr":8410, "reg_count":6, "cycle": 0},
{"name":"inter_group", "reg_addr":8240, "reg_count":10, "cycle": 0},
]
def func_comm_table_trigger_check(object_comm_table, comm_table_item) :
return False
menu_normal_set = [
{
"name": "给定压力",
"unit": "Mpa",
"addr": "40415",
"scale" : 0.001,
"format": "%05.3f",
},
{
"name": "上限压差", #"压力上限",
"unit": "Mpa",
"addr": "40417", #"2419",
"scale" : 0.001,
"format": "%05.3f",
},
{
"name": "下限压差", #"压力下限",
"unit": "Mpa",
"addr": "40418", #"2418",
"scale" : 0.001,
"format": "%05.3f",
},
# {
# "name": "唤醒压差",
# "addr": "40318",
# "scale": 0.001,
# "unit": "Mpa",
# "format": "%05.3f",
# },
{
"name": "休眠功率*",
"addr": "44203",
"scale": 0.01,
"unit": "kW",
"format": "%05.2f",
"action": "SelfPumpOffset8",
},
{
"name": "超压报警",
"unit": "Mpa",
"addr": "40289",
"scale" : 0.001,
"format": "%05.3f",
},
# {
# "name": "定时切换",
# "unit": "Min",
# "addr": "40282",
# "scale" : 1.0,
# "format": "%04.0f",
# },
{
"name": "泵号",
"addr": "40194",
"scale" : 1.0,
"format": "%1.0f",
},
{
"name": "水泵台数",
"addr": "40283",
"scale" : 1.0,
"format": "%1.0f",
"min" : 1,
"max" : 6,
},
{
"name": "最大台数", #爆管台数
"addr": "40285",
"scale" : 1.0,
"format": "%1.0f",
"min" : 1,
"max" : 6,
},
{
"name": "辅泵编号",
"addr": "40284",
"scale" : 1.0,
"format": "%1.0f",
},
{
"name": "进水压力",
"alias" : "alias_bool",
"addr": "40226",
},
{
"name": "水箱液位传感器",
"alias" : "alias_bool",
"addr": "40258",
},
{
"name": "参数同步",
"action": "sync_3",
},
]
menu_func_set = [
{
"name": "水箱1配置",
"sub_menu": "menu_tank1",
},
{
"name": "水箱2配置",
"sub_menu": "menu_tank2",
},
{
"name": "泵组进压阀",
"sub_menu": "menu_pump_inletvalve",
},
{
"name": "水箱市政切换设置",
"sub_menu": "menu_tank_switch",
},
{
"name": "分时压力",
"sub_menu": "menu_time_pressure",
},
{
"name": "程序功能",
"alias": "alias_plc",
"addr": "43983",
"action": "reboot_global",
},
{
"name": "GPRS泵号",
"format": "%1.0f",
"addr": "54201", #"48402",
},
# {
# "name": "通讯设置",
# "sub_menu": "menu_comm_set",
# },
{
"name": "流量计型号",
"alias": "alias_flowmeter",
"addr": "54200", #"48400",
},
{
"name": "流量计泵号",
"format": "%1.0f",
"addr": "54205", #"48410",
},
# {
# "name": "调峰功能",
# "alias": "alias_bool",
# "addr": "40000",
# },
{
"name": "退出",
"action": "exit",
},
]
menu_run_set = [
{
"name": "加泵频率",
"scale" : 0.01,
"unit" : "Hz",
"format": "%06.2f",
"addr": "40278",
},
{
"name": "减泵频率",
"scale" : 0.01,
"unit" : "Hz",
"format": "%06.2f",
"addr": "40279",
},
{
"name": "加泵功率",
"addr": "40276",
"scale": 0.01,
"unit": "KW",
"format": "%05.2f",
},
{
"name": "减泵功率",
"addr": "40277",
"scale": 0.01,
"unit": "KW",
"format": "%05.2f",
},
{
"name": "加泵延时",
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "40280",
},
{
"name": "减泵延时",
"scale" : 0.1,
"unit" : "S",
"format": "%04.1f",
"addr": "40273",
},
{
"name": "休眠频率",
"scale" : 0.01,
"unit" : "Hz",
"format": "%06.2f",
"addr": "40316",
},
{
"name": "休眠延时",
"scale" : 0.1,
"unit" : "S",
"format": "%06.1f",
"addr": "40317",
},
{
"name": "休眠功率*",
"addr": "44203",
"scale": 0.01,
"unit": "kW",
"format": "%05.2f",
"action": "SelfPumpOffset8",
},
{
"name": "功率均衡",
"alias": "alias_bool",
"addr": "40391",
},
{
"name": "均衡死区",
"addr": "40388",
"unit": "%",
"scale": 0.1,
"format": "%05.1f",
},
{
"name": "定时换泵",
"alias": "alias_bool",
"addr": "40281.0",
},
{
"name": "换泵周期",
"addr": "40282",
"unit": "Min",
"format": "%05.0f",
},
]
menu_protect_set = [
# {
# "name": "超压保护",
# "alias": "alias_bool",
# "addr": "40289.2",
# },
{
"name": "超压报警",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40289",
},
{
"name": "负压保护",
"alias": "alias_bool",
"addr": "40288.5",
},
{
"name": "负压报警",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40290",
},
{
"name": "真空报警",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40291",
},
{
"name": "负压解除",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40292",
},
{
"name": "真空解除",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40305",
},
{
"name": "无水液位",
"scale" : 0.01,
"unit" : "m",
"format": "%04.2f",
"addr": "40293",
},
{
"name": "无水解除",
"scale" : 0.01,
"unit" : "m",
"format": "%04.2f",
"addr": "40294",
},
{
"name": "防冻时间",
"addr": "40403",
"unit": "S",
"format": "%04.0f",
},
{
"name": "防冻周期",
"addr": "40404",
"unit": "Min",
"format": "%04.0f",
},
]
menu_data_pump = [
{
"name": "水泵台数",
"addr": "40283",
"scale" : 1.0,
"format": "%1.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "辅泵编号",
"addr": "40284",
"scale" : 1.0,
"format": "%1.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "总电量",
"scale" : 1.0,
"unit" : "kwh",
"format": "%1.0f",
"addr": "53932#2", #"47864#2", "40010#2", GD7864
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispInverseCtrl_59102.12", #10205.4 M205.4 电表通讯成功
},
{
"name": "总功率",
"scale" : 0.1,
"unit" : "kW",
"format": "%1.1f",
"addr": "50585", #"40012", GW1170
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispInverseCtrl_59102.12", #10205.4 M205.4 电表通讯成功
},
{
"name": "电表电量",
"scale" : 1.0,
"unit" : "kwh",
"format": "%1.0f",
"addr": "53932#2", #"47864#2", "40010#2", GD7864
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_59102.12", #10205.4 M205.4 电表通讯成功
},
{
"name": "电表功率",
"scale" : 0.1,
"unit" : "kW",
"format": "%1.1f",
"addr": "50585", #"40012", GW1170
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_59102.12", #10205.4 M205.4 电表通讯成功
},
{
"name": "入水压力",
"scale" : 0.001,
"unit" : "Mpa",
"format": "%1.3f",
"addr": "40023",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A2",
},
{
"name": "出水压力",
"scale" : 0.001,
"unit" : "Mpa",
"format": "%1.3f",
"addr": "40025",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A1",
},
{
"name": "1#液位",
"unit": "m",
"scale" : 0.01,
"addr": "56329", #"39955",
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A3",
},
{
"name": "2#液位",
"unit": "m",
"scale" : 0.01,
"addr": "56291", #"39970",
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A18",
},
{
"name": "3#液位",
"unit": "m",
"scale" : 0.01,
"addr": "56283", #"39973",
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A21",
},
{
"name": "输出流量",
"unit": "m³/h",
"scale" : 0.01,
"addr": "56060#2", #FD120
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A5",
},
{
"name": "输出累计",
"unit": "",
"scale" : 0.001,
"addr": "56072#2", #FD144
"format": "%1.0f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A5",
},
{
"name": "输入流量",
"unit": "m³/h",
"scale" : 0.01,
"addr": "56070#2", #FD140
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A10",
},
{
"name": "输入累计",
"unit": "",
"scale" : 0.001,
"addr": "56074#2", #FD148
"format": "%1.0f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A10",
},
{
"name": "阀门开度",
"unit": "%",
"scale" : 0.1,
"addr": "56299",
"format": "%1.1f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A4",
},
{
"name": "开度2",
"unit": "%",
"scale" : 0.1,
"addr": "56289",
"format": "%1.1f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A17",
},
{
"name": "余氯值",
"unit": "mg/L",
"scale" : 0.01,
"addr": "56317",
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A7",
},
{
"name": "浊度值",
"unit": "NTU",
"scale" : 0.01,
"addr": "56319",
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A8",
},
{
"name": "PH值",
"unit": "",
"scale" : 0.01,
"addr": "56321",
"format": "%1.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A9",
},
{
"name": "水温",
"unit": "",
"scale" : 0.1,
"addr": "56469",
"format": "%+1.1f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A6",
},
{
"name": "噪音分贝",
"unit": "DB",
"scale" : 0.1,
"addr": "56295",
"format": "%1.1f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A19",
},
{
"name": "站内湿度",
"unit": "%",
"scale" : 0.1,
"addr": "56293",
"format": "%1.1f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A20",
},
{
"name": "站内温度",
"unit": "",
"scale" : 0.1,
"addr": "56287",
"format": "%+1.1f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A16",
},
{
"name": "夹层温度",
"unit": "",
"scale" : 0.1,
"addr": "56285",
"format": "%+1.1f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A15",
},
]
menu_data_Native1 = [
{
"name": "当前泵号*",
"addr": "40194",
"scale" : 1.0,
"format": "%1.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "本次运行*",
"unit" : "Min",
"format": "%05.0f",
"addr": "40042#2", #"56342#2",
"property": MENU_PROPERTY_READ_ONLY,
"action": "SelfPumpOffset16",
},
{
"name": "累计运行*",
"scale" : 0.016667,
"unit" : "h",
"format": "%6.0f",
"addr": "40044#2", #"56344#2",
"property": MENU_PROPERTY_READ_ONLY,
"action": "SelfPumpOffset16",
},
{
"name": "当前频率*",
"scale" : 0.01,
"unit" : "Hz",
"format": "%06.2f",
"addr": "40041",
"property": MENU_PROPERTY_READ_ONLY,
"action": "SelfPumpOffset16",
},
{
"name": "当前转速*",
"scale" : 1,
"unit" : "rpm",
"format": "%06.0f",
"addr": "56233",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "母线电压*",
"scale" : 0.1,
"unit" : "V",
"format": "%05.1f",
"addr": "40050", #"46350",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "变频温度*",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "40048", #"56348",
"property": MENU_PROPERTY_READ_ONLY,
"action": "SelfPumpOffset16",
},
{
"name": "电机温度*",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "56346",
"action": "SelfPumpOffset16",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "当前功率*",
"scale" : 0.01,
"unit" : "kW",
"format": "%05.2f",
"addr": "40051", #"45351",
"action": "SelfPumpOffset16",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "额定功率*",
"scale" : 0.01,
"unit" : "kW",
"format": "%05.2f",
"addr": "44017",
"action": "SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "输出电流*",
"scale" : 0.1,
"unit" : "A",
"format": "%05.1f",
"addr": "40049", #"56349",
"action": "SelfPumpOffset16",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "额定电流*",
"scale" : 0.1,
"unit" : "A",
"format": "%05.2f",
"addr": "44018", #"56834",
"action": "SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
]
menu_data_Native2 = [
{
"name": "泵电量*",
"scale" : 1.0,
"unit" : "kwh",
"format": "%07.0f",
"addr": "40008#2",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "泵功率*",
"scale" : 0.01,
"unit" : "kw",
"format": "%05.2f",
"addr": "40007",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "加速时间*",
"unit": "S",
"addr": "44013",
"scale" : 0.1,
"format": "%04.1f",
"action": "FreqParaStop_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "减速时间*",
"unit": "S",
"addr": "44014",
"scale" : 0.1,
"format": "%04.1f",
"action": "FreqParaStop_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "频率上限*",
"unit": "Hz",
"addr": "44015",
"scale" : 0.01,
"format": "%06.2f",
"action": "FreqParaStop_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "频率下限*",
"unit": "Hz",
"addr": "44016",
"scale" : 0.01,
"format": "%06.2f",
"action": "FreqParaStop_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "蓝牙状态",
"alias": "alias_bluetooth",
"addr": "40270",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "通讯地址*",
"addr": "43000",
"scale": 1.0,
"format": "%03.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "通讯1*",
"alias": "alias_comm",
"addr": "43005",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "通讯2*",
"alias": "alias_comm",
"addr": "43006",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水泵流量*",
"addr": "48033",
"scale": 0.1,
"unit": "m³/h",
"format": "%04.1f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水泵扬程*",
"addr": "48032",
"unit": "m",
"format": "%04.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
]
menu_data_user = [
{
"name": "漏水PX0",
"alias": "alias_PX",
"addr": "47612",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "烟感PX1",
"alias": "alias_PX",
"addr": "47614",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "故障PX2",
"alias": "alias_PX",
"addr": "47616",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "门禁PX4",
"alias": "alias_PX",
"addr": "47618",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水箱长度",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54000", #"48000",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水箱宽度",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54001", #"48002",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水箱高度",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54002", #"48004",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水箱容积",
"scale" : 0.01,
"unit" : "",
"format": "%05.2f",
"addr": "46004",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水箱面积",
"scale" : 0.01,
"unit" : "",
"format": "%05.2f",
"addr": "46022",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "水箱功能",
"addr": "54061", #"48122",
"alias": "alias_run_function",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "阀门动作", #默认120.0s
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "54062", #"48124",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "储水总量",
"scale" : 0.01,
"unit" : "",
"format": "%05.2f",
"addr": "46008",
"property": MENU_PROPERTY_READ_ONLY,
},
]
cur_curve = [
{
"name": "退出",
"action": "exit",
},
]
menu_quick_tag = [
{
"name": "泵组工作时间统计",
"sub_menu" : "menu_statistic",
},
{
"name": "故障查询",
"sub_menu" : "menu_alarm_history",
},
{
"name": "压力曲线",
"sub_menu" : "cur_curve",
},
{
"name": "通信设置",
"sub_menu" : "menu_comm_set",
},
{
"name": "信号配置",
"sub_menu" : "memu_sensor_engineer",
},
{
"name": "用户参数",
"sub_menu" : "menu_parameter",
},
{
"name": "联机设置",
"sub_menu" : "menu_link",
},
{
"name": "工程师菜单",
"sub_menu" : "menu_full_set",
},
{
"name": "重启",
"action": "reboot",
},
]
menu_time_pressure = [
{
"name": "分时段压力使能",
"addr": "40281.3",
"alias": "alias_bool",
},
{
"name": "分时段1",
"addr": "40320#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力1",
"addr": "40320",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
{
"name": "分时段2",
"addr": "40328#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力2",
"addr": "40328",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
{
"name": "分时段3",
"addr": "40336#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力3",
"addr": "40336",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
{
"name": "分时段4",
"addr": "40344#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力4",
"addr": "40344",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
{
"name": "分时段5",
"addr": "40352#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力5",
"addr": "40352",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
{
"name": "分时段6",
"addr": "40360#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力6",
"addr": "40360",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
{
"name": "分时段7",
"addr": "40368#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力7",
"addr": "40368",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
{
"name": "分时段8",
"addr": "40376#8",
"action": "pressure_time_ctrl",
},
{
"name": "分时段压力8",
"addr": "40376",
"scale": 0.001,
"format": "%05.3f",
"unit": "Mpa",
},
]
menu_hand_adjust = [
{
"name": "只写页",
},
]
disp_hand_adjust = [ #手动控制页面
{
"name": "OutPressure",
"format": "%4.0f",
"addr": "40025",
},
{
"name": "FreqSet", #手动设定频率
"format": "%5.0f",
"addr": "44010",
"action": "SelfPumpOffset24",
},
{
"name": "FreqCur", #变频器当前频率频率
"format": "%5.0f",
"addr": "40041",
"action": "SelfPumpOffset16",
},
]
menu_link = [
{
"name": "1#模式",
"alias": "alias_workmode2",
"addr": "44009.1#2",
"action" : "work_mode"
},
{
"name": "2#模式",
"alias": "alias_workmode2",
"addr": "44033.1#2",
"action" : "work_mode"
},
{
"name": "3#模式",
"alias": "alias_workmode2",
"addr": "44057.1#2",
"action" : "work_mode"
},
{
"name": "4#模式",
"alias": "alias_workmode2",
"addr": "44081.1#2",
"action" : "work_mode"
},
{
"name": "5#模式",
"alias": "alias_workmode2",
"addr": "44105.1#2",
"action" : "work_mode"
},
{
"name": "6#模式",
"alias": "alias_workmode2",
"addr": "44129.1#2",
"action" : "work_mode"
},
]
menu_alarm_history = [
{
"name": "泵组故障查询",
"action": "alarm_pump_-1",
},
{
"name": "泵1故障查询",
"action": "alarm_pump_0",
},
{
"name": "泵2故障查询",
"action": "alarm_pump_1",
},
{
"name": "泵3故障查询",
"action": "alarm_pump_2",
},
{
"name": "泵4故障查询",
"action": "alarm_pump_3",
},
{
"name": "泵5故障查询",
"action": "alarm_pump_4",
},
{
"name": "泵6故障查询",
"action": "alarm_pump_5",
},
{
"name": "清除故障",
"sub_menu": "menu_alarm_clear",
},
{
"name": "退出",
"action": "exit",
},
]
menu_alarm = [
{
"name": "清除本次故障",
"action": "alarm_clear",
},
{
"name": "历史故障查询",
"sub_menu": "menu_alarm_history",
},
]
menu_curve_history = [
{
"name": "只读页",
},
]
menu_comm_set = [
{
"name": "485地址*",
"addr": "43000",
"scale": 1.0,
"format": "%03.0f",
},
{
"name": "485波特率1*",
"alias": "alias_baud",
"addr": "43001",
},
{
"name": "485校验1*",
"alias": "alias_parity",
"addr": "43002",
},
{
"name": "485波特率2*",
"alias": "alias_baud",
"addr": "43003",
},
{
"name": "485校验2*",
"alias": "alias_parity",
"addr": "43004",
},
{
"name": "485设备1*",
"alias": "alias_comm",
"addr": "43005",
},
{
"name": "485设备2*",
"alias": "alias_comm",
"addr": "43006",
},
{
"name": "IP地址*",
"addr": "43009#2",
"action" : "ip",
},
{
"name": "子网掩码*",
"action": "ip",
"addr": "43011#2",
},
{
"name": "IP网关*",
"action": "ip",
"addr": "43013#2",
},
{
"name": "蓝牙*",
"addr": "48028",
"alias" : "alias_bool",
},
{
"name": "蓝牙地址*",
"action": "bluetooth_addr",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "退出",
"action": "exit",
},
]
menu_parameter = [
{
"name": "GPRS泵号",
"addr": "54201", #"48402",
"scale": 1.0,
"format": "%01.0f",
},
{
"name": "PLC通讯主机泵号",
"format": "%1.0f",
"addr": "54205", #48410
},
{
"name": "PLC电度表选择",
"alias": "alias_Energymeter",
"addr": "54206", #48412
},
{
"name": "PLC输出流量计",
"alias": "alias_flowmeter",
"addr": "54200", #48400
},
{
"name": "PLC输入流量计",
"alias": "alias_flowmeter",
"addr": "54202", #48404
},
{
"name": "PLC水质分析仪",
"format": "%1.0f",
"addr": "54208", #48416
"alias": "alias_waterquality",
},
{
"name": "PLC温湿度选型",
"alias": "alias_temp_wet",
"addr": "54209", #48418
},
{
"name": "PLC夹层温度",
"alias": "alias_tempmiddle",
"addr": "54211", #48422
},
{
"name": "PLC噪声变送器",
"alias": "alias_noise",
"addr": "54212", #48424
},
{
"name": "脚位配置",
"alias": "alias_plc_pin",
"addr": "54130", #48260
"action": "reboot_global",
},
# {
# "name": "脚本输出流量计*",
# "alias": "alias_flowmeter",
# "addr": "54151", #"48302",
# "action" : "SelfPumpOffset8",
# "action": "reboot_global",
# },
# {
# "name": "脚本输入流量计*",
# "alias": "alias_flowmeter",
# "addr": "54152",#48304
# "action" : "SelfPumpOffset8",
# "action": "reboot_global",
# },
# {
# "name": "脚本电表选择*",
# "alias": "alias_Energymeter",
# "addr": "54156", #48312
# "action" : "SelfPumpOffset8",
# "action": "reboot_global",
# },
# {
# "name": "脚本温湿度选型*",
# "alias": "alias_temp_wet",
# "addr": "54150", #48300
# "action" : "SelfPumpOffset8",
# },
# {
# "name": "脚本噪声变送器*",
# "alias": "alias_noise",
# "addr": "54153", #48306
# "action" : "SelfPumpOffset8",
# },
# {
# "name": "脚本水质分析仪*",
# "alias": "alias_waterquality",
# "addr": "54154", #48308
# "action" : "SelfPumpOffset8",
# },
# {
# "name": "脚本夹层温度*",
# "alias": "alias_tempmiddle",
# "addr": "54155", #48310
# "action" : "SelfPumpOffset8",
# },
{
"name": "退出",
"action": "exit",
},
]
menu_temp_control = [
{
"name": "空调功能",
"addr": "54088", #"48176",
"alias": "alias_run_function",
},
{
"name": "空调上限温度",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "54085", #"48170",
},
{
"name": "空调下限温度",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "54086", #"48172",
},
{
"name": "空调开启时长",
"scale" : 1.0,
"unit" : "Min",
"format": "%06.0f",
"addr": "54087", #"48174",
},
{
"name": "手动空调开启*",
"action" : "KeyEnterTrigger_DispCtrl_54088.1",#48176.1
"addr": "59060.12", #"10121.4",
},
{
"name": "手动空调关闭*",
"action" : "KeyEnterTrigger_DispCtrl_54088.1",
"addr": "59060.13", #"10121.5",
},
{
"name": "加热器功能",
"addr": "54082", #"48164",
"alias": "alias_run_function",
},
{
"name": "加热开启温度",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "54080", #"48160",
},
{
"name": "加热关闭温度",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "54081", #"48162",
},
{
"name": "手动加热开启*",
"action" : "KeyEnterTrigger_DispCtrl_54082.1",#48164.1
"addr": "59060.10", #"10121.2",
},
{
"name": "手动加热关闭*",
"action" : "KeyEnterTrigger_DispCtrl_54082.1",
"addr": "59060.11", #"10121.3",
},
]
menu_tank1 = [
{
"name": "液位1传感器",
"alias": "alias_bool",
"addr": "40258", #400 = FW600 + 516 = FW1116
},
{
"name": "1#液位",
"unit": "m",
"scale" : 0.01,
"addr": "56329", #"39955",
"format": "%05.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A3",
},
{
"name": "1#水箱功能",
"addr": "54061", #"48122",
"alias": "alias_run_function",
},
{
"name": "1#手动开阀",
"addr": "59060.0", #"10120.0",
"action" : "KeyEnterTrigger_DispCtrl_54061.1",#48122.1
},
{
"name": "1#手动关阀",
"addr": "59060.1", #"10120.1",
"action" : "KeyEnterTrigger_DispCtrl_54061.1",
},
{
"name": "1#开阀输出",
"addr": "59086.13", #"10173.5",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "1#关阀输出",
"addr": "59086.14", #"10173.6",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "1#开阀到位",
"addr": "59122.3", #"10244.3",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "1#关阀到位",
"addr": "59122.4", #"10244.4",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "1#阀门动作时长", #默认120.0s
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "54062", #"48124",
},
{
"name": "1#开阀液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "56595", #"1190",
},
{
"name": "1#关阀液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "56596", #"1192",
},
{
"name": "无水液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "56593", #"1186",
},
{
"name": "无水解除",
"scale" : 0.01,
"unit" : "m",
"format": "%04.2f",
"addr": "40294",
},
{
"name": "水箱长度",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54000", #"48000",
},
{
"name": "水箱宽度",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54001", #"48002",
},
{
"name": "水箱高度",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54002", #"48004",
},
]
menu_tank2 = [
{
"name": "液位2传感器",
"alias" : "alias_bool",
"addr": "43942",
},
{
"name": "2#液位",
"unit": "m",
"scale" : 0.01,
"addr": "56291", #"39970",
"format": "%05.2f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "Visible_A18",
},
{
"name": "2#水箱功能",
"addr": "54056", #"48112",
"alias": "alias_run_function",
},
{
"name": "2#手动开阀",
"addr": "59060.2", #"10120.2",
"action" : "KeyEnterTrigger_DispCtrl_54056.1",#48112.1
},
{
"name": "2#手动关阀",
"addr": "59060.3", #"10120.3",
"action" : "KeyEnterTrigger_DispCtrl_54056.1",
},
{
"name": "2#开阀输出",
"addr": "59086.15", #"10173.7",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "2#关阀输出",
"addr": "59087.0", #"10174.0",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "2#开阀到位",
"addr": "59082.1", #"10164.1",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "2#关阀到位",
"addr": "59082.2", #"10164.2",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
},
{
"name": "2#阀门动作时长", #默认120s
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "54057", #"48114",
},
{
"name": "2#开阀液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54054", #"48108",
},
{
"name": "2#关阀液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54055", #"48110",
},
]
menu_tank3 = [
{
"name": "3#水箱功能",
"addr": "54073", #"48146",
"alias": "alias_run_function",
},
{
"name": "3#手动开阀",
"addr": "59059.8", #"10119.0",
"action" : "KeyEnterTrigger_DispCtrl_54073.1",#48146.1
},
{
"name": "3#手动关阀",
"addr": "59059.9", #"10119.1",
"action" : "KeyEnterTrigger_DispCtrl_54073.1",
},
{
"name": "3#阀门动作时长", #默认120s
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "54084", #"48168",
},
{
"name": "3#开阀液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54074", #"48148",
},
{
"name": "3#关阀液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "54083", #"48166",
},
]
menu_tank_switch = [
{
"name": "水箱市政切换",
"addr": "54100", #"48200",
"alias": "alias_run_function",
},
{
"name": "切换手动开阀",
"addr": "59061.2", #"10122.2",
"action" : "KeyEnterTrigger_DispCtrl_54100.1",#48200.1
},
{
"name": "切换手动关阀",
"addr": "59061.3", #"10122.3",
"action" : "KeyEnterTrigger_DispCtrl_54100.1",
},
{
"name": "切换开阀输出",
"addr": "59087.8", #"10175.0",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54100",
},
{
"name": "切换关阀输出",
"addr": "59087.9", #"10175.1",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54100",
},
{
"name": "切换开阀到位",
"addr": "59082.15", #"10165.7",
"alias": "alias_valve_status",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54100",
},
{
"name": "切换关阀到位",
"addr": "59083.0", #"10166.0",
"alias": "alias_valve_status",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54100",
},
{
"name": "阀门动作延时",
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "54117", #"48234",
},
{
"name": "时段一始",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54108", #"48216",
},
{
"name": "时段一终",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54109", #"48218",
},
{
"name": "时段二始",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54110", #"48220",
},
{
"name": "时段二终",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54111", #"48222",
},
{
"name": "时段三始",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54112", #"48224",
},
{
"name": "时段三终",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54113", #"48226",
},
{
"name": "时段四始",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54114", #48228",
},
{
"name": "时段四终",
"scale" : 0.01,
"unit" : "时:分",
"min" : "00#00",
"max" : "23#59",
"format": "%05.2f",
"addr": "54115", #"48230",
},
]
menu_pump_inletvalve = [
{
"name": "进压阀门功能",
"addr": "54069", #"48138",
"alias": "alias_run_function",
},
{
"name": "进水压力",
"unit": "Mpa",
"scale" : 0.001,
"addr": "40023",
"format": "%05.2f",
},
{
"name": "手动进压开阀",
"addr": "59060.6", #"10120.6",
"action" : "KeyEnterTrigger_DispCtrl_54069.1", #48138.1
},
{
"name": "手动进压关阀",
"addr": "59060.7", #"10120.7",
"action" : "KeyEnterTrigger_DispCtrl_54069.1", #48138.1
},
{
"name": "进压开阀输出",
"addr": "59087.3", #"10174.3",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54069",
},
{
"name": "进压关阀输出",
"addr": "59087.4", #"10174.4",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54069",
},
{
"name": "开阀到位状态",
"alias": "alias_valve_status",
"addr": "59082.11", #"10165.3",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54069", #48138
},
{
"name": "关阀到位状态",
"alias": "alias_valve_status",
"addr": "59082.12", #"10165.4",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54069", #48138
},
{
"name": "进水有效延时",
"scale" : 0.001,
"unit" : "S",
"format": "%06.3f",
"min" : 1.0,
"max" : 65.535,
"addr": "54068", #"48136",
},
{
"name": "开阀压力值",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "54066", #"48132",
},
{
"name": "关阀压力值",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "54065", #"48130",
},
{
"name": "阀门动作时长",
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "54067", #"48134",
},
]
menu_explosion_valve = [
{
"name": "爆管阀门功能",
"addr": "54072", #"48144",
"alias": "alias_run_function",
},
{
"name": "手动爆管开阀",
"addr": "59060.4", #"10120.4",
"action" : "KeyEnterTrigger_DispCtrl_54072.1", #48144.1
},
{
"name": "手动爆管关阀",
"addr": "59060.5", #"10120.5",
"action" : "KeyEnterTrigger_DispCtrl_54072.1", #48144.1
},
{
"name": "漏水信号",
"addr": "59080.7", #"10160.7",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54072", #48144
},
{
"name": "爆管开阀输出",
"addr": "59087.1", #"10174.1",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54072", #48144
},
{
"name": "爆管关阀输出",
"addr": "59087.2", #"10174.2",
"alias" : "alias_bool",
"property" : MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54072", #48144
},
{
"name": "爆管开阀到位",
"alias": "alias_valve_status",
"addr": "59082.6", #"10164.6",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54072", #48144
},
{
"name": "爆管关阀到位",
"alias": "alias_valve_status",
"addr": "59082.7", #"10164.7",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "DispCtrl_54072", #48144
},
{
"name": "阀门工作时长",
"scale" : 0.1,
"unit" : "S",
"format": "%05.1f",
"addr": "54071", #"48142",
},
{
"name": "爆管信号延时",
"unit" : "ms",
"format": "%05.0f",
"addr": "54070", #"48140",
},
]
menu_peripheral = [
{
"name": "照明功能",
"addr": "54095", #"48190",
"alias": "alias_run_function",
},
{
"name": "照明手动开",
"addr": "59061.0", #"10122.0",
"action" : "KeyEnterTrigger_DispCtrl_54095.1",#48190.1
},
{
"name": "照明手动关",
"addr": "59061.1", #10122.1",
"action" : "KeyEnterTrigger_DispCtrl_54095.1",
},
{
"name": "门禁功能",
"alias": "alias_run_function",
"addr": "54105", #"48210",
},
{
"name": "门禁手动开",
"addr": "59060.14", #"10121.6",
"action" : "KeyEnterTrigger_DispCtrl_54105.1",#48210.1
},
{
"name": "门禁手动关",
"addr": "59060.15", #"10121.7",
"action" : "KeyEnterTrigger_DispCtrl_54105.1",
},
]
menu_fan_arefaction = [
{
"name": "风机功能",
"addr": "54079", #"48158",
"alias": "alias_run_function",
},
{
"name": "风机开启温度",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "54075", #"48150",
},
{
"name": "风机关闭温度",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "54076", #"48152",
},
{
"name": "风机手动开",
"addr": "59060.8", #"10121.0",
"action" : "KeyEnterTrigger_DispCtrl_54079.1",#48158.1
},
{
"name": "风机手动关",
"addr": "59060.9", #"10121.1",
"action" : "KeyEnterTrigger_DispCtrl_54079.1",
},
{
"name": "除湿机功能",
"addr": "54092", #"48184",
"alias": "alias_run_function",
},
{
"name": "除湿机开启湿度",
"scale" : 0.1,
"unit" : "%",
"format": "%05.1f",
"addr": "54090", #"48180",
},
{
"name": "除湿机关闭湿度",
"scale" : 0.1,
"unit" : "%",
"format": "%05.1f",
"addr": "54091", #"48182",
},
{
"name": "除湿机手动开",
"addr": "59060.14", #"10121.6",
"action" : "KeyEnterTrigger_DispCtrl_54092.1",#48184.1
},
{
"name": "除湿机手动关",
"addr": "59060.15", #"10121.7",
"action" : "KeyEnterTrigger_DispCtrl_54092.1",
},
]
menu_pin_configure = [
{
"name": "X0.1(X1)*",
"alias": "alias_input",
"addr": "44265",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset22",
},
{
"name": "X0.3(X3)*",
"alias": "alias_input",
"addr": "44267",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset22",
},
{
"name": "X0.4(X4)*",
"alias": "alias_input",
"addr": "44268",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset22",
},
{
"name": "X0.5(X5)*",
"addr": "44269",
"alias": "alias_input",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset22",
},
{
"name": "X0.6(X6)*",
"alias": "alias_input",
"addr": "44270",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset22",
},
{
"name": "Y0.0(A1-B1)*",
"alias": "alias_output",
"addr": "44272",
"action" : "SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "Y0.1(A2-B2)*",
"alias": "alias_output",
"addr": "44273",
"action" : "SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "Y0.3(A4-B4)*",
"alias": "alias_output",
"addr": "44275",
"action" : "SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
]
menu_statistic = [
{
"name": "所有泵统计",
"action": "pumps_statistic",
},
{
"name": "当前压力曲线",
"sub_menu": "cur_curve",
},
{
"name": "当前工作时间",
"addr": "40042#2",
"unit": "Min",
"format": "%09.0f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset16",
},
{
"name": "累计工作时间",
"addr": "40044#2",
"unit": "Min",
"format": "%09.0f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset16",
},
{
"name": "累计工作次数",
"addr": "40054#2",
"unit": "",
"format": "%09.0f",
"property": MENU_PROPERTY_READ_ONLY,
"action" : "SelfPumpOffset16",
},
{
"name": "累计清零",
"action": "clear_acc_time",
"property": MENU_PROPERTY_ENGINEER,
},
{
"name": "累计电量清零",
"action": "clear_kwh",
"property": MENU_PROPERTY_ENGINEER,
},
{
"name": "退出",
"action": "exit",
},
]
menu_system = [
{
"name": "硬件版本*",
"addr": "48013",
"scale" : 0.01,
"format": "%05.2f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "系统版本*",
"addr": "48031",
"scale" : 0.01,
"format": "%04.2f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "PLC版本*",
"addr": "50499", #"40998",
"scale" : 0.01,
"format": "%04.2f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "序列号*",
"addr": "44024#2",
"format": "%09.0f",
"action" : "SerialId_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "系统日期",
"addr": "40408#3",
"action" : "date",
},
{
"name": "当前时间",
"addr": "40411#3",
"action" : "time",
},
{
"name": "语言*",
"addr": "48014",
"alias": "alias_language",
},
{
"name": "提示音*",
"addr": "48029",
"alias" : "alias_bool",
},
{
"name": "锁定键盘*",
"action" : "lock",
},
{
"name": "背光亮度*",
"addr": "48009",
"unit": "%",
"min": 10,
"max": 100,
"format": "%03.0f",
},
{
"name": "背光延时*",
"addr": "48008",
"unit": "S",
"format": "%04.0f",
},
{
"name": "退出",
"action": "exit",
},
]
menu_protect = [
{
"name": "负压保护",
"alias": "alias_bool",
"addr": "40288.5",
},
{
"name": "负压报警值",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40290",
},
{
"name": "真空报警值",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40291",
},
{
"name": "负压报警解除值",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40292",
},
{
"name": "真空报警解除值",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40305",
},
{
"name": "超压报警",
"unit": "Mpa",
"addr": "40289",
"scale" : 0.001,
"format": "%05.3f",
},
{
"name": "爆管保护",
"alias": "alias_bool",
"addr": "40288.8",
},
{
"name": "爆管停机压力",
"scale" : 0.001,
"unit" : "MPa",
"format": "%05.3f",
"addr": "40297",
},
{
"name": "爆管停机延时",
"scale" : 0.1,
"unit" : "S",
"format": "%04.1f",
"addr": "40298",
},
{
"name": "电机温度上限",
"scale" : 0.1,
"unit" : "",
"format": "%05.1f",
"addr": "40392",
},
{
"name": "水箱无水保护",
"alias": "alias_bool",
"addr": "40289.7", #FW600 + 598.7 = FW1198.7
},
{
"name": "无水液位",
"scale" : 0.01,
"unit" : "m",
"format": "%05.2f",
"addr": "56593",
},
{
"name": "无水解除",
"scale" : 0.01,
"unit" : "m",
"format": "%04.2f",
"addr": "40294",
},
{
"name": "退出",
"action": "exit",
},
]
menu_sleep_set = [
{
"name": "休眠功率*",
"addr": "44203",
"scale": 0.01,
"unit": "kW",
"format": "%05.2f",
"action": "SelfPumpOffset8",
},
{
"name": "休眠频率",
"scale" : 0.01,
"unit" : "Hz",
"format": "%06.2f",
"addr": "40316",
},
{
"name": "休眠延时",
"addr": "40317",
"scale": 0.1,
"unit": "S",
"format": "%06.1f",
},
{
"name": "休眠提升时间*",
"addr": "44206",
"scale": 0.1,
"unit": "S",
"format": "%05.1f",
"action" : "SelfPumpOffset8",
},
{
"name": "唤醒延时",
"addr": "40319",
"scale": 0.01,
"unit": "S",
"format": "%05.2f",
},
{
"name": "唤醒压差",
"addr": "40318",
"scale": 0.001,
"unit": "Mpa",
"format": "%05.3f",
},
{
"name": "退出",
"action": "exit",
},
]
menu_pump_adjust_set = [
{
"name": "减泵压差",
"scale" : 0.001,
"unit" : "Mpa",
"format": "%05.3f",
"addr": "40274",
},
{
"name": "加泵压差",
"scale": 0.001,
"unit": "Mpa",
"format": "%05.3f",
"addr": "40275",
},
{
"name": "休眠加泵压差", #频率在休眠频率以下时的加泵压力差,可以加快加泵速度。
"scale": 0.001,
"unit": "Mpa",
"format": "%05.3f",
"addr": "40306",
},
{
"name": "加泵延时",
"addr": "40280",
"scale": 0.1,
"unit": "S",
"format": "%05.1f",
},
{
"name": "减泵延时",
"addr": "40273",
"scale": 0.1,
"unit": "S",
"format": "%04.1f",
},
{
"name": "功率到达加泵",
"addr": "40272.0",
"alias": "alias_bool",
},
{
"name": "加泵功率",
"addr": "40276",
"scale": 0.01,
"unit": "KW",
"format": "%05.2f",
},
{
"name": "功率到达减泵",
"addr": "40272.1",
"alias": "alias_bool",
},
{
"name": "减泵功率",
"addr": "40277",
"scale": 0.01,
"unit": "KW",
"format": "%05.2f",
},
{
"name": "频率到达加泵",
"addr": "40272.2",
"alias": "alias_bool",
},
{
"name": "加泵频率",
"addr": "40278",
"scale": 0.01,
"unit": "Hz",
"format": "%06.2f",
},
{
"name": "频率到达减泵",
"addr": "40272.3",
"alias": "alias_bool",
},
{
"name": "减泵频率",
"addr": "40279",
"scale": 0.01,
"unit": "Hz",
"format": "%06.2f",
},
{
"name": "退出",
"action": "exit",
},
]
menu_pid_set = [
{
"name": "启动PID类型",
"addr": "40304",
"alias": "alias_pid",
},
{
"name": "启动PID Kp",
"addr": "40307",
"scale": 0.001,
"format": "%05.3f",
},
{
"name": "启动PID Ti",
"addr": "40308",
"scale": 0.01,
"unit": "S",
"format": "%06.2f",
},
{
"name": "启动PID Td",
"addr": "40309",
"scale": 0.01,
"unit": "S",
"format": "%06.2f",
},
{
"name": "动态PID类型",
"addr": "40395",
"alias": "alias_pid",
},
{
"name": "动态PID Kp",
"addr": "40396",
"scale": 0.001,
"format": "%05.3f",
},
{
"name": "动态PID Ti",
"addr": "40397",
"scale": 0.01,
"unit": "S",
"format": "%06.2f",
},
{
"name": "动态PID Td",
"addr": "40398",
"scale": 0.01,
"unit": "S",
"format": "%06.2f",
},
{
"name": "动态PID进入",
"addr": "40394",
"scale": 0.01,
"unit": "%",
"format": "%05.2f",
},
{
"name": "动态PID退出",
"addr": "40393",
"scale": 0.01,
"unit": "%",
"format": "%05.2f",
},
{
"name": "PID死区",
"addr": "40314",
"scale": 0.01,
"unit": "%",
"format": "%06.2f",
},
{
"name": "PID调节周期",
"addr": "40311",
"unit": "ms",
"format": "%04.0f",
},
{
"name": "PID负载",
"addr": "40406",
"alias": "alias_pidmode",
},
{
"name": "退出",
"action": "exit",
},
]
menu_winter_set = [
{
"name": "防冻使能",
"alias": "alias_bool",
"addr": "40401",
},
{
"name": "运行频率/下限",
"addr": "40402",
"unit": "%",
"format": "%03.0f",
},
{
"name": "防冻运行时间",
"addr": "40403",
"unit": "S",
"format": "%04.0f",
},
{
"name": "防冻周期",
"addr": "40404",
"unit": "Min",
"format": "%04.0f",
},
{
"name": "退出",
"action": "exit",
},
]
menu_pumpgroup = [
{
"name": "加减泵设置",
"sub_menu": "menu_pump_adjust_set",
},
{
"name": "休眠设置",
"sub_menu": "menu_sleep_set",
},
{
"name": "常用设置",
"sub_menu": "menu_normal_set",
},
{
"name": "功能设置",
"sub_menu": "menu_func_set",
},
{
"name": "主辅设置",
"sub_menu": "menu_host_set",
},
{
"name": "防冻设置",
"sub_menu": "menu_winter_set",
},
{
"name": "程序功能",
"alias": "alias_plc",
"addr": "43983",
"action": "reboot_global",
},
{
"name": "参数同步",
"action": "sync_3",
},
{
"name": "定时换泵",
"alias": "alias_bool",
"addr": "40281.0",
},
{
"name": "定时换泵周期",
"addr": "40282",
"unit": "Min",
"format": "%05.0f",
"min": 10,
"max": 480,
"default": 360,
},
{
"name": "换泵冷却时间",
"addr": "40303",
"scale": 1.0,
"unit": "Min",
"format": "%05.0f",
},
{
"name": "水泵流量*",
"addr": "48033",
"scale": 0.1,
"unit": "m³/h",
"format": "%04.1f",
},
{
"name": "水泵扬程*",
"addr": "48032",
"unit": "m",
"format": "%04.0f",
},
{
"name": "退出",
"action": "exit",
},
]
menu_full_set = [ #工程师菜单的专属设置
{
"name": "信号配置",
"sub_menu": "memu_sensor_engineer",
},
{
"name": "泵组PID配置",
"sub_menu": "menu_pid_set",
},
{
"name": "变频器参数",
"sub_menu": "menu_freq_convert",
},
{
"name": "系统信息",
"sub_menu": "menu_system_engineer",
},
{
"name": "模拟量传感器",
"sub_menu": "memu_sensor_config",
},
{
"name": "数字IO测试",
"sub_menu": "test_io",
},
{
"name": "模拟IO测试",
"sub_menu": "test_aio",
},
{
"name": "用户参数",
"sub_menu": "menu_parameter",
},
{
"name": "重启",
"action": "reboot",
},
# {
# "name": "常规设置",
# "sub_menu": "menu_system",
# },
# {
# "name": "设置",
# "sub_menu": "menu_normal_set",
# },
{
"name": "退出",
"action": "exit",
},
]
memu_sensor_engineer = [ #工程师菜单的专属设置
{
"name": "开关量输入配置",
"sub_menu": "menu_io_in",
},
{
"name": "开关量输出配置",
"sub_menu": "menu_io_out",
},
{
"name": "模拟量输入配置",
"sub_menu": "menu_aio_in",
},
{
"name": "模拟量输出配置",
"sub_menu": "menu_aio_out",
},
{
"name": "AI1 AD值",
"addr": "56206", #FW412
"format": "%05.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "AI3 AD值",
"addr": "56208", #FW416
"format": "%05.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "AI4 AD值",
"addr": "56209", #FW418
"format": "%05.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "退出",
"action": "exit",
},
]
menu_io_out= [
{
"name": "A1-B1*",
"alias": "alias_output",
"addr": "44272",
"action": "SelfPumpOffset22",
},
{
"name": "A2-B2*",
"alias": "alias_output",
"addr": "44273",
"action": "SelfPumpOffset22",
},
{
"name": "A4-B4",
"alias": "alias_output",
"addr": "44275",
"action": "SelfPumpOffset22",
},
]
menu_io_in= [
{
"name": "X1*",
"alias": "alias_input",
"addr": "44265",
"action": "SelfPumpOffset22",
},
#{
# "name": "X2*",
# "alias": "alias_input",
# "addr": "44266",
# "action": "SelfPumpOffset22",
#},
{
"name": "X3*",
"alias": "alias_input",
"addr": "44267",
"action": "SelfPumpOffset22",
},
{
"name": "X4*",
"alias": "alias_input",
"addr": "44268",
"action": "SelfPumpOffset22",
},
{
"name": "X5*",
"alias": "alias_input",
"addr": "44269",
"action": "SelfPumpOffset22",
},
{
"name": "X6*",
"alias": "alias_input",
"addr": "44270",
"action": "SelfPumpOffset22",
},
]
menu_aio_out= [
{
"name": "AO2*",
"alias": "alias_aioutput",
"addr": "44285",
"action": "SelfPumpOffset22",
},
{
"name": "AO2 4mA*",
"addr": "48053",
"format": "%04.0f",
"min" : 0,
"max" : 4095,
},
{
"name": "AO2 20mA*",
"addr": "48054",
"format": "%04.0f",
"min" : 0,
"max" : 4095,
},
]
menu_aio_in= [
{
"name": "AI1*",
"alias": "alias_aiinput",
"addr": "44280",
"action" : "SelfPumpOffset22"
},
{
"name": "AI3*",
"alias": "alias_aiinput",
"addr": "44282",
"action" : "SelfPumpOffset22"
},
{
"name": "AI4*",
"alias": "alias_aiinput",
"addr": "44283",
"action" : "SelfPumpOffset22"
},
{
"name": "AI1配置",
"sub_menu": "menu_aio_set1",
},
{
"name": "AI3配置",
"sub_menu": "menu_aio_set2",
},
{
"name": "AI4配置",
"sub_menu": "menu_aio_set3",
},
{
"name": "AO校正",
"sub_menu": "menu_ao_cal",
},
{
"name": "退出",
"action": "exit",
},
]
menu_aio_set1= [
{
"name": "当前AD值",
"format" : "%05.0f",
"addr": "56206",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "AD值10V",
"format": "%04.0f",
"addr": "48047",
},
{
"name": "设为AD值10V",
"action":"AI_Calibrate0",
},
{
"name": "AI1模式",
"addr": "44271.0",
"alias": "alias_anaolog_mode",
"action": "SelfPumpOffset22",
},
{
"name": "退出",
"action": "exit",
},
]
menu_aio_set2= [
{
"name": "当前AD值",
"format" : "%05.0f",
"addr": "56208",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "AD值10V",
"format": "%04.0f",
"addr": "48049",
},
{
"name": "设为AD值10V",
"action":"AI_Calibrate2",
},
{
"name": "AI3模式",
"addr": "44271.1",
"alias": "alias_anaolog_mode",
"action": "SelfPumpOffset22",
},
{
"name": "退出",
"action": "exit",
},
]
menu_aio_set3= [
{
"name": "当前AD值",
"format" : "%05.0f",
"addr": "56209",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "AD值10V",
"format": "%04.0f",
"addr": "48050",
},
{
"name": "设为AD值10V",
"action":"AI_Calibrate3",
},
{
"name": "AI1模式",
"addr": "44271.2",
"alias": "alias_anaolog_mode",
"action": "SelfPumpOffset22",
},
{
"name": "退出",
"action": "exit",
},
]
menu_ao_cal = [
{
"name": "模拟量输出",
"format" : "%05.0f",
"addr": "48061",
"min" : 0,
"max" : 32000,
"action":"AO_Calibrate",
},
{
"name": "4mA输出标定",
"action":"AO_Calibrate4mA",
},
{
"name": "20mA输出标定",
"action":"AO_Calibrate20mA",
},
{
"name": "AO1模式",
"addr": "44271.3",
"alias": "alias_anaolog_mode",
"action": "SelfPumpOffset22",
},
{
"name": "退出",
"action": "exit",
},
]
# menu_pump_engineer = [ #工程师菜单的专属设置
# ]
menu_freq_convert = [
{
"name": "自动复位限制",
"addr": "40301",
"unit": "",
"format": "%02.0f",
},
{
"name": "累计复位次数",
"addr": "40197",
"unit": "",
"format": "%02.0f",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "加速时间*",
"unit": "S",
"addr": "44013",
"scale" : 0.1,
"format": "%04.1f",
"action": "FreqParaStop_SelfPumpOffset24",
},
{
"name": "减速时间*",
"unit": "S",
"addr": "44014",
"scale" : 0.1,
"format": "%04.1f",
"action": "FreqParaStop_SelfPumpOffset24",
},
{
"name": "启动时间*",
"unit": "S",
"addr": "44020",
"scale" : 0.1,
"format": "%05.1f",
"action": "FreqParaStop_SelfPumpOffset24",
},
{
"name": "载波频率*",
"unit": "kHz",
"scale" : 0.1,
"format": "%04.1f",
"addr": "44019",
"action": "FreqParaStop_SelfPumpOffset24",
},
{
"name": "频率上限*",
"unit": "Hz",
"addr": "44015",
"scale" : 0.01,
"format": "%06.2f",
"action": "FreqParaStop_SelfPumpOffset24",
},
{
"name": "频率下限*",
"unit": "Hz",
"addr": "44016",
"scale" : 0.01,
"format": "%06.2f",
"action": "FreqParaStop_SelfPumpOffset24",
},
{
"name": "额定频率*",
"unit": "Hz",
"addr": "44012",
"scale" : 0.01,
"format": "%06.2f",
"action": "FreqParaStop_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "额定功率*",
"unit": "Kw",
"addr": "56833",
"scale" : 0.01,
"format": "%05.2f",
"action": "FreqParaStop_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "额定电流*",
"unit": "A",
"addr": "56834",
"scale" : 0.1,
"format": "%04.1f",
"action": "FreqParaStop_SelfPumpOffset24",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "退出",
"action": "exit",
},
]
menu_system_engineer = [ #工程师菜单的专属设置
# {
# "name": "变频器选择",
# "alias" : "alias_converter",
# "addr": "48012",
# },
# {
# "name": "权限管理",
# "action": "admin",
# },
{
"name": "系统密码*",
"addr": "48041",
"format" :"%04.0f",
"action": "password",
},
{
"name": "恢复出厂设置",
"sub_menu": "menu_factory_default",
},
{
"name": "备份还原点1",
"sub_menu": "menu_save_restore1",
},
{
"name": "备份还原点2",
"sub_menu": "menu_save_restore2",
},
{
"name": "序列号*",
"addr": "48002#2",
"format": "%10.0f",
"action": "SerialId_Modify",
},
{
"name": "累计运行*",
"scale" : 0.016667,
"unit" : "h",
"format": "%07.0f",
"addr": "40044#2", #"56344#2",
"action": "SelfPumpOffset16",
"property": MENU_PROPERTY_ENGINEER,
},
{
"name": "退出",
"action": "exit",
},
]
#显示1台泵
menu_run_data1 = [
{
"name": "转速*",
},
{
"name": "电流*",
},
{
"name": "功率*",
},
{
"name": "时间*",
},
]
#显示2台泵
menu_run_data2 = [
{
"name": "转速*",
},
{
"name": "电流*",
},
{
"name": "功率*",
},
{
"name": "时间*",
},
]
#显示3台泵
menu_run_data3 = [
{
"name": "转速*",
},
{
"name": "电流*",
},
{
"name": "功率*",
},
{
"name": "时间*",
},
]
#模拟IO测试
test_aio = [
{
"name": "AO2",
"addr" : "48060",
"scale" : 0.1,
"format" : "%05.1f",
"unit" : "%",
},
]
#数字IO测试
test_io = [
{
"name": "Y1",
"addr" : "44272",
"alias" : "alias_output",
"action" : "TestY0_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "Y2",
"addr" : "44273",
"alias" : "alias_output",
"action" : "TestY1_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "Y3",
"addr" : "44275",
"alias" : "alias_output",
"action" : "TestY3_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "X1",
"addr" : "44265",
"alias" : "alias_input",
"action" : "TestX1_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "X2",
"addr" : "44266",
"alias" : "alias_input",
"action" : "TestX2_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "X3",
"addr" : "44267",
"alias" : "alias_input",
"action" : "TestX3_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "X4",
"addr" : "44268",
"alias" : "alias_input",
"action" : "TestX4_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "X5",
"addr" : "44269",
"alias" : "alias_input",
"action" : "TestX5_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "X6",
"addr" : "44270",
"alias" : "alias_input",
"action" : "TestX6_SelfPumpOffset22",
"property": MENU_PROPERTY_READ_ONLY,
},
]
menu_pressure_in = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40226", # FW600 + 452 = FW1052
},
{
"name": "全局值",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "40023",
},
{
"name": "本机值*",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "56124",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40022",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40230",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40229",
},
{
"name": "量程下限*",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "40228",
},
{
"name": "量程上限*",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "40227",
},
{
"name": "退出",
"action": "exit",
},
]
menu_pressure_out = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40234", #FW600 + 468 = FW1068
},
{
"name": "全局值",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "40025",
},
{
"name": "本机值*",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "56123",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40024",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40238",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40237",
},
{
"name": "量程下限*",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "40236",
},
{
"name": "量程上限*",
"format": "%05.3f",
"scale": 0.001,
"unit": "Mpa",
"addr": "40235",
},
{
"name": "退出",
"action": "exit",
},
]
menu_valve_opening = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43910",
},
{
"name": "全局值",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "39999",
},
{
"name": "本机值*",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "56126",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "39998",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43914",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43913",
},
{
"name": "量程下限*",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "43912",
},
{
"name": "量程上限*",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "43911",
},
{
"name": "退出",
"action": "exit",
},
]
menu_water_level2 = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43942",
},
{
"name": "全局值",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "56291",
},
{
"name": "本机值*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "56140",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56290",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43946",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43945",
},
{
"name": "量程下限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "43944",
},
{
"name": "量程上限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "43943",
},
{
"name": "退出",
"action": "exit",
},
]
menu_water_level3 = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43974",
},
{
"name": "全局值",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "56285",
},
{
"name": "本机值*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "56143",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56284",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43978",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43977",
},
{
"name": "量程下限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "43976",
},
{
"name": "量程上限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "43975",
},
{
"name": "退出",
"action": "exit",
},
]
menu_temp = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40250",
},
{
"name": "全局值",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "40169#s",
},
{
"name": "本机值*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "56128#s",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40168",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40254",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40253",
},
{
"name": "量程下限*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "40252#s",
},
{
"name": "量程上限*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "40251#s",
},
{
"name": "退出",
"action": "exit",
},
]
menu_temp_inside = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43958",
},
{
"name": "全局值",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "56287#s",
},
{
"name": "本机值*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "56138#s",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56286",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43962",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43961",
},
{
"name": "量程下限*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "43960#s",
},
{
"name": "量程上限*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "43959#s",
},
{
"name": "退出",
"action": "exit",
},
]
menu_temp_middle = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43966",
},
{
"name": "全局值",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "56285#s",
},
{
"name": "本机值*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "56137#s",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56284",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43970",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43969",
},
{
"name": "量程下限*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "43968#s",
},
{
"name": "量程上限*",
"format": "%+06.1f",
"scale": 0.1,
"unit": "",
"addr": "43967#s",
},
{
"name": "退出",
"action": "exit",
},
]
menu_water_level= [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40258",
},
{
"name": "全局值",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "40029",
},
{
"name": "本机值*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "56125",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40028",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40262",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40261",
},
{
"name": "量程下限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "40260",
},
{
"name": "量程上限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m",
"addr": "40259",
},
{
"name": "退出",
"action": "exit",
},
]
menu_valve_opening2 = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43950",
},
{
"name": "全局值",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "56289",
},
{
"name": "本机值*",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "56140",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56288",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43954",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43953",
},
{
"name": "量程下限*",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "43952",
},
{
"name": "量程上限*",
"format": "%05.1f",
"scale": 0.1,
"unit": "%",
"addr": "43951",
},
{
"name": "退出",
"action": "exit",
},
]
menu_chlorine = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40202",
},
{
"name": "本机值*",
"format": "%06.2f",
"scale": 0.01,
"unit": "%",
"addr": "56129",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40016",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40206",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40205",
},
{
"name": "量程下限*",
"format": "%06.2f",
"scale": 0.01,
"unit": "%",
"addr": "40204",
},
{
"name": "量程上限*",
"format": "%06.2f",
"scale": 0.01,
"unit": "%",
"addr": "40203",
},
{
"name": "退出",
"action": "exit",
},
]
menu_dirty = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40210",
},
{
"name": "本机值*",
"format": "%06.2f",
"scale": 0.01,
"unit": "%",
"addr": "56130",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40018",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40214",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40213",
},
{
"name": "量程下限*",
"format": "%06.2f",
"scale": 0.01,
"unit": "%",
"addr": "40212",
},
{
"name": "量程上限*",
"format": "%06.2f",
"scale": 0.01,
"unit": "%",
"addr": "40211",
},
{
"name": "退出",
"action": "exit",
},
]
menu_flow_out = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40242",
},
{
"name": "全局值",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "40027",
},
{
"name": "本机值*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "56127",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40026",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40246",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40245",
},
{
"name": "量程下限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "40244",
},
{
"name": "量程上限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "40243",
},
{
"name": "退出",
"action": "exit",
},
]
menu_flow_in = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43918",
},
{
"name": "全局值",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "56297",
},
{
"name": "本机值*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "56132",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56296",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43922",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43921",
},
{
"name": "量程下限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "43920",
},
{
"name": "量程上限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "m³/h",
"addr": "43919",
},
{
"name": "退出",
"action": "exit",
},
]
menu_ph_sensor = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "40218",
},
{
"name": "全局值",
"format": "%05.2f",
"scale": 0.01,
"addr": "40021",
},
{
"name": "本机值*",
"format": "%05.2f",
"scale": 0.01,
"addr": "56131",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "40020",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "40222",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "40221",
},
{
"name": "量程下限*",
"format": "%05.2f",
"scale": 0.01,
"addr": "40220",
},
{
"name": "量程上限*",
"format": "%05.2f",
"scale": 0.01,
"addr": "40219",
},
{
"name": "退出",
"action": "exit",
},
]
menu_wet_sensor = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43926",
},
{
"name": "全局值",
"format": "%05.2f",
"scale": 0.01,
"unit": "%",
"addr": "56293",
},
{
"name": "本机值*",
"format": "%05.2f",
"scale": 0.01,
"unit": "%",
"addr": "56142",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56292",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43930",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43929",
},
{
"name": "量程下限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "%",
"addr": "43928",
},
{
"name": "量程上限*",
"format": "%05.2f",
"scale": 0.01,
"unit": "%",
"addr": "43927",
},
{
"name": "退出",
"action": "exit",
},
]
menu_sound_sensor = [
{
"name": "配置",
"alias" : "alias_bool",
"addr": "43934",
},
{
"name": "全局值",
"format": "%05.1f",
"scale": 0.1,
"unit": "db",
"addr": "56295",
},
{
"name": "本机值*",
"format": "%05.1f",
"scale": 0.1,
"unit": "db",
"addr": "56141",
},
{
"name": "AD值*",
"format": "%05.0f",
"addr": "56294",
"property": MENU_PROPERTY_READ_ONLY,
},
{
"name": "ADMin*",
"format": "%05.0f",
"addr": "43938",
},
{
"name": "ADMax*",
"format": "%05.0f",
"addr": "43937",
},
{
"name": "量程下限*",
"format": "%05.1f",
"scale": 0.1,
"unit": "db",
"addr": "43936",
},
{
"name": "量程上限*",
"format": "%05.1f",
"scale": 0.1,
"unit": "db",
"addr": "43935",
},
{
"name": "退出",
"action": "exit",
},
]
#信号配置
memu_sensor_config = [
{
"name": "输入压力传感器",
"sub_menu": "menu_pressure_in",
},
{
"name": "输出压力传感器",
"sub_menu": "menu_pressure_out",
},
{
"name": "输入流量传感器",
"sub_menu": "menu_flow_in",
},
{
"name": "输出流量传感器",
"sub_menu": "menu_flow_out",
},
{
"name": "水箱液位1",
"sub_menu": "menu_water_level",
},
{
"name": "水箱液位2",
"sub_menu": "menu_water_level2",
},
{
"name": "水箱液位3",
"sub_menu": "menu_water_level3",
},
{
"name": "调节阀开度反馈",
"sub_menu": "menu_valve_opening",
},
{
"name": "开度反馈2",
"sub_menu": "menu_valve_opening2",
},
{
"name": "温度传感器",
"sub_menu": "menu_temp",
},
{
"name": "站内温度传感器",
"sub_menu": "menu_temp_inside",
},
{
"name": "夹层温度传感器",
"sub_menu": "menu_temp_middle",
},
{
"name": "余氯传感器",
"sub_menu": "menu_chlorine",
},
{
"name": "浊度传感器",
"sub_menu": "menu_dirty",
},
{
"name": "PH传感器",
"sub_menu": "menu_ph_sensor",
},
{
"name": "湿度传感器",
"sub_menu": "menu_wet_sensor",
},
{
"name": "噪音传感器",
"sub_menu": "menu_sound_sensor",
},
{
"name": "退出",
"action": "exit",
},
]
menu_main = [
{
"name": "设置",
"sub_menu": "menu_normal_set",
},
{
"name": "数据",
"sub_menu": "menu_data_pump"
},
{
"name": "模式",
"sub_menu": "menu_mode"
},
{
"name": "菜单",
"sub_menu": "menu_normal_menu"
},
]
menu_normal_menu = [ #普通菜单页面
{
"name": "系统信息",
"sub_menu": "menu_system",
},
{
"name": "泵组配置",
"sub_menu": "menu_pumpgroup",
},
{
"name": "保护设置",
"sub_menu": "menu_protect",
},
{
"name": "故障查询",
"sub_menu": "menu_alarm",
},
{
"name": "通信设置",
"sub_menu": "menu_comm_set",
},
{
"name": "用户参数",
"sub_menu": "menu_parameter",
},
{
"name": "工程师菜单",
"sub_menu": "menu_full_set",
},
{
"name": "恢复出厂设置",
"sub_menu": "menu_factory_default",
},
{
"name": "重启",
"action": "reboot",
},
{
"name": "退出",
"action": "exit",
},
]
menu_script_desc = [
{
"name": "脚本 V1.08",
},
{
"name": "输出流量:10, 输入流量:11",
},
{
"name": "噪声传感器: 通讯地址=7",
},
{
"name": "温湿度传感器: 通讯地址=8",
},
{
"name": "水质分析仪: 通讯地址=5",
},
{
"name": "夹层温度: 通讯地址=9",
},
{
"name": "电度表: 通讯地址=6",
},
]
menu_factory_default = [
{
"name": "恢复到本机",
"action": "self_restore_0",
},
{
"name": "恢复到全局",
"action": "global_restore_0",
},
{
"name": "退 出",
"action": "exit",
},
]
menu_save_restore1 = [
{
"name": "保存",
"action": "save_1",
},
{
"name": "恢复到本机",
"action": "self_restore_1",
},
{
"name": "恢复到全局",
"action": "global_restore_1",
},
{
"name": "退 出",
"action": "exit",
},
]
menu_save_restore2 = [
{
"name": "保存",
"action": "save_2",
},
{
"name": "恢复到本机",
"action": "self_restore_2",
},
{
"name": "恢复到全局",
"action": "global_restore_2",
},
{
"name": "退 出",
"action": "exit",
},
]
display_main = [
{
"name": "PumpName",
"alias": "alias_PumpName",
"addr" : "48000", #PumpId
},
{
"name": "PressureOutMax", #输出压力上限
"format": "%4.0f",
"addr" : "40235",
},
{
"name": "设定压力",
"addr": "40416",
"format": "%4.0f",
},
]
menu_host_set = [
{
"name": "主辅泵优先级",
"addr": "40299",
"alias": "alias_priority",
},
{
"name": "辅泵编号",
"addr": "40284",
"scale" : 1.0,
"format": "%1.0f",
},
{
"name": "辅泵切换延时",
"addr": "40300",
"scale": 0.1,
"unit": "S",
"format": "%05.1f",
},
{
"name": "辅泵切换功率",
"addr": "40302",
"scale": 0.01,
"unit": "KW",
"format": "%05.2f",
},
{
"name": "参数同步",
"action": "sync_3",
},
{
"name": "退出",
"action": "exit",
},
]
menu_caption = [
{"name" : "menu_main", "menu" : menu_main, "caption": "主菜单", "page" : 2, "max_items" : 4, "next" : menu_link, "prev": menu_hand_adjust, "display": display_main},
{"name" : "display_main", "menu" : display_main, "caption": "display_main", "page" : 2, "max_items" : 4},
{"name" : "menu_link", "menu" : menu_link, "caption": "联机设置", "page" : 4, "max_items" : 6, "next" : menu_run_data1, "prev" : menu_main},
{"name" : "menu_run_data1", "menu" : menu_run_data1, "caption": "数据页1", "page" : 3, "max_items" : 1, "next" : menu_alarm, "prev" : menu_link},
{"name" : "menu_run_data2", "menu" : menu_run_data2, "caption": "数据页2", "page" : 13, "max_items" : 1, "next" : menu_alarm, "prev" : menu_link},
{"name" : "menu_run_data3", "menu" : menu_run_data3, "caption": "数据页3", "page" : 23, "max_items" : 1, "next" : menu_alarm, "prev" : menu_link},
{"name" : "menu_alarm", "menu" : menu_alarm, "caption": "报警显示", "page" : 5, "max_items" : 2, "next" : menu_curve_history, "prev" : menu_run_data1},
{"name" : "menu_curve_history", "menu" : menu_curve_history, "caption": "历史曲线", "page" : 25, "max_items" : 1, "next" : menu_hand_adjust, "prev" : menu_alarm},
{"name" : "menu_hand_adjust", "menu" : menu_hand_adjust, "caption": "手动调速", "page" : 15, "max_items" : 1, "next" : menu_main, "prev" : menu_curve_history, "display": disp_hand_adjust},
{"name" : "disp_hand_adjust", "menu" : disp_hand_adjust, "caption": "显示调速", "page" : 15, "max_items" : 1},
{"name" : "menu_alarm_history", "menu" : menu_alarm_history, "caption": "历史故障", "page" : 11, "max_items" : 8},
{"name" : "dynamic_page_main", "menu" : dynamic_page_main, "caption": "测量数据", "page" : 2, "max_items" : 4},
{"name" : "mqtt_pack_alarm", "menu" : mqtt_pack_alarm, "caption": "报警数据", "page" : 5, "max_items" : 8},
{"name" : "menu_sleep_set", "menu" : menu_sleep_set, "caption": "休眠设置", "page" : 11, "max_items" : 8},
{"name" : "menu_winter_set", "menu" : menu_winter_set, "caption": "防冻设置", "page" : 11, "max_items" : 8},
{"name" : "menu_pump_adjust_set", "menu" : menu_pump_adjust_set, "caption": "加减泵设置", "page" : 11, "max_items" : 8},
{"name" : "menu_pumpgroup", "menu" : menu_pumpgroup, "caption": "泵组配置", "page" : 11, "max_items" : 8},
{"name" : "memu_sensor_config", "menu" : memu_sensor_config, "caption": "模拟量传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_system", "menu" : menu_system, "caption": "系统信息", "page" : 11, "max_items" : 8},
{"name" : "menu_protect", "menu" : menu_protect, "caption": "保护设置", "page" : 11, "max_items" : 8},
{"name" : "menu_full_set", "menu" : menu_full_set, "caption": "工程师菜单", "page" : 11, "max_items" : 8},
{"name" : "menu_normal_menu", "menu" : menu_normal_menu, "caption": "普通菜单", "page" : 11, "max_items" : 8},
{"name" : "menu_comm_set", "menu" : menu_comm_set, "caption": "通讯设置", "page" : 11, "max_items" : 8},
{"name" : "menu_statistic", "menu" : menu_statistic, "caption": "统计信息", "page" : 11, "max_items" : 8},
{"name" : "menu_time_pressure", "menu" : menu_time_pressure, "caption": "分时段压力", "page" : 11, "max_items" : 8},
{"name" : "cur_curve", "menu" : cur_curve, "caption": "当前压力", "page" : 12, "max_items" : 1},
{"name" : "menu_io_out", "menu" : menu_io_out, "caption": "开关量输出配置", "page" : 11, "max_items" : 8},
{"name" : "menu_io_in", "menu" : menu_io_in, "caption": "开关量输入配置", "page" : 11, "max_items" : 8},
{"name" : "menu_aio_out", "menu" : menu_aio_out, "caption": "模拟量输出配置", "page" : 11, "max_items" : 8},
{"name" : "menu_aio_in", "menu" : menu_aio_in, "caption": "模拟量输入配置", "page" : 11, "max_items" : 8},
{"name" : "menu_aio_set1", "menu" : menu_aio_set1, "caption": "模拟输入校正1", "page" : 11, "max_items" : 8},
{"name" : "menu_aio_set2", "menu" : menu_aio_set2, "caption": "模拟输入校正2", "page" : 11, "max_items" : 8},
{"name" : "menu_aio_set3", "menu" : menu_aio_set3, "caption": "模拟输入校正3", "page" : 11, "max_items" : 8},
{"name" : "menu_ao_cal", "menu" : menu_ao_cal, "caption": "模拟输出标定", "page" : 11, "max_items" : 8},
#工程师菜单
{"name" : "menu_freq_convert", "menu" : menu_freq_convert, "caption": "变频器参数", "page" : 11, "max_items" : 8},
{"name" : "memu_sensor_engineer","menu" : memu_sensor_engineer,"caption": "信号配置", "page" : 11, "max_items" : 8},
{"name" : "menu_system_engineer","menu" : menu_system_engineer,"caption": "系统信息", "page" : 11, "max_items" : 8},
#{"name" : "menu_pump_engineer", "menu" : menu_pump_engineer, "caption": "泵组PID配置", "page" : 11, "max_items" : 8},
{"name" : "test_io", "menu" : test_io, "caption": "数字IO测试", "page" : 7, "max_items" : 9},
{"name" : "test_aio", "menu" : test_aio, "caption": "模拟IO测试", "page" : 8, "max_items" : 1},
{"name" : "menu_factory_default", "menu" : menu_factory_default, "caption": "恢复出厂设置", "page" : 11, "max_items" : 8},
{"name" : "menu_save_restore1", "menu" : menu_save_restore1, "caption": "备份还原点1", "page" : 11, "max_items" : 8},
{"name" : "menu_save_restore2", "menu" : menu_save_restore2, "caption": "备份还原点2", "page" : 11, "max_items" : 8},
{"name" : "menu_pid_set", "menu" : menu_pid_set, "caption": "泵组PID配置", "page" : 11, "max_items" : 8},
#传感器
{"name" : "menu_pressure_in", "menu" : menu_pressure_in, "caption": "输入压力传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_pressure_out", "menu" : menu_pressure_out, "caption": "输出压力传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_water_level", "menu" : menu_water_level, "caption": "水箱液位传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_water_level2", "menu" : menu_water_level2, "caption": "水箱液位2", "page" : 11, "max_items" : 8},
{"name" : "menu_water_level3", "menu" : menu_water_level3, "caption": "水箱液位3", "page" : 11, "max_items" : 8},
{"name" : "menu_temp", "menu" : menu_temp, "caption": "温度传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_temp_inside", "menu" : menu_temp_inside, "caption": "站内温度传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_temp_middle", "menu" : menu_temp_middle, "caption": "夹层温度传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_valve_opening", "menu" : menu_valve_opening, "caption": "调节阀开度反馈", "page" : 11, "max_items" : 8},
{"name" : "menu_valve_opening2", "menu" : menu_valve_opening2,"caption": "开度反馈2", "page" : 11, "max_items" : 8},
{"name" : "menu_flow_out", "menu" : menu_flow_out, "caption": "输出流量传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_flow_in", "menu" : menu_flow_in, "caption": "输入流量传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_chlorine", "menu" : menu_chlorine, "caption": "余氯传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_dirty", "menu" : menu_dirty, "caption": "浊度传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_ph_sensor", "menu" : menu_ph_sensor, "caption": "PH传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_wet_sensor", "menu" : menu_wet_sensor, "caption": "湿度传感器", "page" : 11, "max_items" : 8},
{"name" : "menu_sound_sensor", "menu" : menu_sound_sensor, "caption": "噪音传感器", "page" : 11, "max_items" : 8},
#设置页面
{"name" : "menu_quick_tag", "menu" : menu_quick_tag, "caption": "快捷入口", "page" : 11, "max_items" : 8, "next" : menu_normal_set, "prev" : menu_protect_set},
{"name" : "menu_normal_set", "menu" : menu_normal_set, "caption": "常用设置", "page" : 6, "max_items" : 12, "next" : menu_run_set, "prev" : menu_quick_tag},
{"name" : "menu_run_set", "menu" : menu_run_set, "caption": "运行设置", "page" : 6, "max_items" : 12, "next" : menu_func_set, "prev" : menu_normal_set},
{"name" : "menu_func_set", "menu" : menu_func_set, "caption": "功能设置", "page" : 11, "max_items" : 8, "next" : menu_protect_set, "prev" : menu_run_set},
{"name" : "menu_protect_set", "menu" : menu_protect_set, "caption": "保护设置", "page" : 6, "max_items" : 12, "next" : menu_quick_tag, "prev" : menu_func_set},
{"name" : "menu_host_set", "menu" : menu_host_set, "caption": "主辅设置", "page" : 11, "max_items" : 8},
#数据页面
{"name" : "menu_data_pump", "menu" : menu_data_pump, "caption": "泵组数据", "page" : 19, "max_items" : 12, "next" : menu_data_Native1, "prev" : menu_data_user},
{"name" : "menu_data_Native1", "menu" : menu_data_Native1, "caption": "本机数据1", "page" : 19, "max_items" : 12, "next" : menu_data_Native2, "prev" : menu_data_pump},
{"name" : "menu_data_Native2", "menu" : menu_data_Native2, "caption": "本机数据2", "page" : 19, "max_items" : 12, "next" : menu_data_user, "prev" : menu_data_Native1},
{"name" : "menu_data_user", "menu" : menu_data_user, "caption": "用户数据", "page" : 19, "max_items" : 12, "next" : menu_data_pump, "prev" : menu_data_Native2},
#用户参数页面
{"name" : "menu_parameter", "menu" : menu_parameter, "caption": "用户参数", "page" : 11, "max_items" : 8, "next" : menu_temp_control, "prev" : menu_pin_configure},
{"name" : "menu_temp_control", "menu" : menu_temp_control, "caption": "调温配置", "page" : 11, "max_items" : 8, "next" : menu_tank1, "prev" : menu_parameter},
{"name" : "menu_tank1", "menu" : menu_tank1, "caption": "1#水箱", "page" : 11, "max_items" : 8, "next" : menu_tank2, "prev" : menu_temp_control},
{"name" : "menu_tank2", "menu" : menu_tank2, "caption": "2#水箱", "page" : 11, "max_items" : 8, "next" : menu_tank3, "prev" : menu_tank1},
{"name" : "menu_tank3", "menu" : menu_tank3, "caption": "3#水箱", "page" : 11, "max_items" : 8, "next" : menu_tank_switch, "prev" : menu_tank2},
{"name" : "menu_tank_switch", "menu" : menu_tank_switch, "caption": "箱罐切换", "page" : 11, "max_items" : 8, "next" : menu_pump_inletvalve, "prev" : menu_tank3},
{"name" : "menu_pump_inletvalve","menu" : menu_pump_inletvalve,"caption": "泵组进压阀门", "page" : 11, "max_items" : 8, "next" : menu_explosion_valve, "prev" : menu_tank_switch},
{"name" : "menu_explosion_valve","menu" : menu_explosion_valve,"caption": "爆管阀门", "page" : 11, "max_items" : 8, "next" : menu_peripheral, "prev" : menu_pump_inletvalve},
{"name" : "menu_peripheral", "menu" : menu_peripheral, "caption": "其他外设", "page" : 11, "max_items" : 8, "next" : menu_fan_arefaction, "prev" : menu_explosion_valve},
{"name" : "menu_fan_arefaction", "menu" : menu_fan_arefaction,"caption": "风机除湿", "page" : 11, "max_items" : 8, "next" : menu_pin_configure, "prev" : menu_peripheral},
{"name" : "menu_pin_configure", "menu" : menu_pin_configure, "caption": "引脚配置", "page" : 11, "max_items" : 8, "next" : menu_script_desc, "prev" : menu_fan_arefaction},
{"name" : "menu_script_desc", "menu" : menu_script_desc, "caption": "脚本描述", "page" : 14, "max_items" : 8, "next" : menu_parameter, "prev" : menu_pin_configure},
]
class class_pump_comm_device_config(class_comm_device_config):
def __init__(self):
class_comm_device_config.__init__(self)
pass
#@override get_alias_table
def get_alias_table(self) :
return alias_table
#@override get_comm_table
def get_comm_table(self) :
return modbus_comm_table, func_comm_table_trigger_check
#@override get_menu_main
def get_menu_top(self) :
return menu_main
#@override get_mqtt_table
def get_mqtt_table(self) :
return mqtt_topic_subscribe
#@override menu_get_display_page
def menu_get_display_page(self, active_menu):
return menu_page.KUNLUN_GRAOUP_PAGE_MENU
def get_menu_caption_info(self) :
return menu_caption
#comm_device_config的名字不要更改, 创建通讯配置类
comm_device_config = class_pump_comm_device_config()